Definition and research guide
This page combines a MeSH definition, publication statistics and selected research abstracts. It is a starting point for reading the literature, not a medical textbook or a systematic evidence review.
Content available: 4 complete abstracts (890 words), 10 references. Full article text is not stored or reproduced here; follow the PMID, DOI or PMC links to read the original sources and their access terms.
Definition
A procedure in which fluid is withdrawn from a body cavity or organ via a trocar and cannula, needle, or other hollow instrument.
Definition: NLM Medical Subject Headings (MeSH) scope note (Public domain (U.S. National Library of Medicine); attribution requested). View the MeSH record.
Also known as: Paracenteses; Centesis; Centeses; Puncture and Drainage; Drainage and Puncture; Puncture and Aspiration; Aspiration and Puncture; Culdocentesis.
Where it fits in the MeSH classification
- Broader topics
- Specimen Handling; Drainage; Punctures
- Narrower topics
- Amniocentesis; Arthrocentesis; Cordocentesis; Pericardiocentesis; Thoracentesis; Tympanocentesis
- See also
- Douglas' Pouch
Research landscape
PubMed indexes 13,810 records tagged with the MeSH heading “Paracentesis” (counts retrieved 2026-11-04). 1,879 of them (13.6%) were published from 2020 onward, and the busiest period so far is through 1999 with 5,781 records.
Reviews account for 1,513 records (11.0%) and meta-analyses for 98. Randomized controlled trials number 326 (2.4%) as a share of all records on the topic.
Show the data
| Period | Records |
|---|---|
| through 1999 | 5,781 |
| 2000-2009 | 2,745 |
| 2010-2019 | 3,405 |
| 2020 onward | 1,879 |
Publication-type chart data
| Type | Records | Share |
|---|---|---|
| Reviews | 1,513 | 11.0% |
| Meta-analyses | 98 | 0.7% |
| Randomized controlled trials | 326 | 2.4% |
Method: PubMed query "Paracentesis"[MeSH Terms] with publication-type and date filters, retrieved 2026-11-04.
Reading the evidence in diagnostics and medical technology
A test or device is judged by how well it detects a condition, how often it gives false alarms or misses cases, and whether using it improves outcomes for people. Accuracy depends on who is tested and how common the condition is, so a test that performs well in a specialist hospital can perform differently in the community. Check the reference standard, the population studied, the sensitivity and specificity and whether results were confirmed in a separate group.
Evidence from open-access studies
These open-access studies come from PubMed’s best-match results for this heading (papers whose main topic it is), ranked here by citation count, with one recent addition. Each abstract is reproduced in full under its recorded open licence so that you can read the authors’ own words. They illustrate the literature; they are not a systematic summary of it. Citation counts measure attention, not reliability or clinical benefit.
| Study / authors | Year | Source label / design | Europe PMC citations | Licence / source |
|---|---|---|---|---|
| Pleural Fluid suPAR Levels Predict the Need for Invasive Management in Parapneumonic Effusions | 2020 | Research article Design not recorded in structured metadata | 44 | cc by PMID 32069085 · DOI · PMC7301729 |
| Ultrasonic aspiration in neurosurgery: comparative analysis of complications and outcome for three commonly used models | 2019 | Research article Design not recorded in structured metadata | 23 | cc by PMID 31377957 · DOI · PMC6739453 |
| Invasive Prenatal Diagnostic Testing for Aneuploidies in Singleton Pregnancies: A Comparative Review of Major Guidelines | 2022 | Review article Design not recorded in structured metadata | 13 | cc by PMID 36295632 · DOI · PMC9609299 |
| Safety and Efficacy of Echo- vs. Fluoroscopy-Guided Pericardiocentesis in Cardiac Tamponade | 2025 | Research article Design not recorded in structured metadata | 4 | cc by PMID 40005382 · DOI · PMC11857578 |
Pleural Fluid suPAR Levels Predict the Need for Invasive Management in Parapneumonic Effusions [1]
Abstract reading summary — source excerpts
- Opening excerpt
- Rationale: Parapneumonic effusions have a wide clinical spectrum.
- Closing excerpt
- These results need validation in a prospective multicenter trial.
- Interpretation limits
- Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (197 words)
Rationale: Parapneumonic effusions have a wide clinical spectrum. The majority settle with conservative management but some progress to complex collections requiring intervention. For decades, physicians have relied on pleural fluid pH to determine the need for chest tube drainage despite a lack of prospective validation and no ability to predict the requirement for fibrinolytics or thoracic surgery.Objectives: To study the ability of suPAR (soluble urokinase plasminogen activator receptor), a potential biomarker of pleural fluid loculation, to predict the need for invasive management compared with conventional fluid biomarkers (pH, glucose, and lactate dehydrogenase) in parapneumonic effusions.Methods: Patients presenting with pleural effusions were prospectively recruited to an observational study with biological samples stored at presentation. Pleural fluid and serum suPAR levels were measured using the suPARnostic double-monoclonal antibody sandwich ELISA on 93 patients with parapneumonic effusions and 47 control subjects (benign and malignant effusions).Measurements and Main Results: Pleural suPAR levels were significantly higher in effusions that were loculated versus nonloculated parapneumonic effusions (median, 132 ng/ml vs. 22 ng/ml; P Conclusions: Raised pleural suPAR was predictive of patients receiving more invasive management of parapneumonic effusions and added value to conventional biomarkers. These results need validation in a prospective multicenter trial.
Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 32069085 · DOI · PMC7301729
Ultrasonic aspiration in neurosurgery: comparative analysis of complications and outcome for three commonly used models [2]
Abstract reading summary — source excerpts
- Opening excerpt
- IntroductionUltrasonic aspiration (UA) devices are commonly used for resecting intracranial tumors, as they allow for internal debulking of large tumors, hereby avoiding damage to adjacent brain tissue during the dissection.
- Closing excerpt
- The safety profiles of three commonly used UA types appear mostly similar.
- Interpretation limits
- Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (271 words)
IntroductionUltrasonic aspiration (UA) devices are commonly used for resecting intracranial tumors, as they allow for internal debulking of large tumors, hereby avoiding damage to adjacent brain tissue during the dissection. Little is known about their comparative safety profiles.Methods and materialsWe analyzed data from a prospective patient registry. Procedures using one of the following UA models were included: Integra® CUSA, Söring®, and Stryker® Sonopet. The primary endpoint was morbidity at discharge, defined as significant worsening on the Karnofsky Performance Scale. Secondary endpoints included morbidity and mortality until 3 months postoperative (M3), occurrence, type, and etiology of complications.ResultsOf n = 1028 procedures, the CUSA was used in n = 354 (34.4 %), the Söring in n = 461 (44.8 %), and the Sonopet in n = 213 (20.7 %). There was some heterogeneity of study groups. In multivariable analysis, patients in the Söring (adjusted odds ratio (aOR) 1.29; 95 % confidence interval (CI), 0.80-2.08; p = 0.299), and Sonopet group (aOR, 0.86; 95 % CI, 0.46-1.61; p = 0.645) were as likely as patients in the CUSA group to experience discharge morbidity. At M3, patients in the Söring (aOR, 1.20; 95 % CI, 0.78-1.86; p = 0.415) and Sonopet group (aOR, 0.53; 95 % CI, 0.26-1.08; p = 0.080) were as likely as patients in the CUSA group to experience morbidity. There were also no differences for M3 morbidity in subgroup analyses for gliomas, meningiomas, and metastases. The grade (p = 0.608) and etiology (p = 0.849) of postoperative complications were similar.ConclusionsNeurosurgeons select UA types with regard to certain case-specific characteristics. The safety profiles of three commonly used UA types appear mostly similar.
Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 31377957 · DOI · PMC6739453
Invasive Prenatal Diagnostic Testing for Aneuploidies in Singleton Pregnancies: A Comparative Review of Major Guidelines [3]
Abstract reading summary — source excerpts
- Opening excerpt
- Sophisticated screening protocols for genetic abnormalities constitute an important component of current prenatal care, aiming to identify high-risk pregnancies and offer appropriate counseling to parents regarding their options.
- Closing excerpt
- The synthesis of an evidence-based algorithm for IPDT is of crucial importance to healthcare professionals implicated in prenatal care to avoid unnecessary interventions without compromising optimal prenatal care.
- Interpretation limits
- Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (185 words)
Sophisticated screening protocols for genetic abnormalities constitute an important component of current prenatal care, aiming to identify high-risk pregnancies and offer appropriate counseling to parents regarding their options. Definite prenatal diagnosis is only possible by invasive prenatal diagnostic testing (IPDT), mainly including amniocentesis and chorionic villous sampling (CVS). The aim of this comparative review was to summarize and compare the existing recommendations on IPDT from the most influential guidelines. All the reviewed guidelines highlight that IPDT is indicated based on a positive screening test rather than maternal age alone. Other indications arise from medical history and sonography, with significant variations identified between the guidelines. The earlier time for amniocentesis is unequivocally set at ≥15 gestational weeks, whereas for CVS, the earlier limit varies from ≥10 to ≥11 weeks. Certain technical aspects and the overall approach demonstrate significant differences. Periprocedural management regarding Rhesus alloimmunization, virologic status and use of anesthesia or antibiotics are either inconsistent or insufficiently addressed. The synthesis of an evidence-based algorithm for IPDT is of crucial importance to healthcare professionals implicated in prenatal care to avoid unnecessary interventions without compromising optimal prenatal care.
Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 36295632 · DOI · PMC9609299
Safety and Efficacy of Echo- vs. Fluoroscopy-Guided Pericardiocentesis in Cardiac Tamponade [4]
Abstract reading summary — source excerpts
- Opening excerpt
- Background and Objectives: Cardiac tamponade is managed through echo- or fluoroscopy-guided percutaneous pericardiocentesis.
- Closing excerpt
- Delaying the procedure for patients with a triage score ≥6, or performing it early for those with a low score, did not impact complication rates or mortality, which were more influenced by the progression of the underlying disease.
- Interpretation limits
- Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (237 words)
Background and Objectives: Cardiac tamponade is managed through echo- or fluoroscopy-guided percutaneous pericardiocentesis. The European Society of Cardiology's Working Group on Myocardial and Pericardial Diseases proposed a triage strategy for these patients. This study evaluated the triage score and compared the safety and efficacy of fluoroscopy- versus echo-guided procedures without additional visualization control. Materials and Methods: This prospective observational study included 71 patients with cardiac tamponade from February 2021 to June 2022. Pericardiocentesis was performed using fluoroscopy or echo guidance based on clinical assessment and catheterization laboratory availability, without the additional control of needle/guidewire position or ECG monitoring. Patients were followed for three months. Results: The study included 71 patients (52.1% female, mean age 59.7 ± 15.7 years). Malignancy was the most common comorbidity (59.2%). Echo criteria led to urgent procedures in 47.9%, with subcostal access used most often (60.6%), particularly in fluoroscopy-guided procedures (93.8%, p = 0.003). The success rate was 97.1%, with minor complications in 14% of patients. Diabetes and malignancy predicted complications regardless of access site or guiding method. The triage score did not affect complication rates or short-term mortality. Conclusions: Fluoroscopy- and echo-guided pericardiocentesis without additional visualization control showed no difference in safety or efficacy. Delaying the procedure for patients with a triage score ≥6, or performing it early for those with a low score, did not impact complication rates or mortality, which were more influenced by the progression of the underlying disease.
Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 40005382 · DOI · PMC11857578
Key reviews and meta-analyses
The most cited review-type papers among PubMed’s best-match results for this heading, listed with bibliographic details only. Follow the links for the full text and access terms.
- Research article Focused cardiac ultrasound in the emergent setting: a consensus statement of the American Society of Echocardiography and American College of Emergency Physicians [5]
- Research article Procedure-related risk of miscarriage following amniocentesis and chorionic villus sampling: a systematic review and meta-analysis [6]
- Research article Acute cardiac tamponade [7]
- Research article Risk of miscarriage following amniocentesis or chorionic villus sampling: systematic review of literature and updated meta-analysis [8]
- Research article ACOG Practice Bulletin No. 88, December 2007. Invasive prenatal testing for aneuploidy [9]
- Research article Pneumothorax following thoracentesis: a systematic review and meta-analysis [10]
References
- Arnold DT, Hamilton FW, Elvers KT, Frankland SW, Zahan-Evans N, Patole S, et al.. Pleural Fluid suPAR Levels Predict the Need for Invasive Management in Parapneumonic Effusions. . 2020. PMID 32069085 · DOI · PMC7301729
- Henzi S, Krayenbühl N, Bozinov O, Regli L, Stienen MN. Ultrasonic aspiration in neurosurgery: comparative analysis of complications and outcome for three commonly used models. . 2019. PMID 31377957 · DOI · PMC6739453
- Giovannopoulou E, Tsakiridis I, Mamopoulos A, Kalogiannidis I, Papoulidis I, Athanasiadis A, et al.. Invasive Prenatal Diagnostic Testing for Aneuploidies in Singleton Pregnancies: A Comparative Review of Major Guidelines. . 2022. PMID 36295632 · DOI · PMC9609299
- Simeunović DS, Milinković I, Polovina M, Trifunović Zamaklar D, Veljić I, Zaharijev S, et al.. Safety and Efficacy of Echo- vs. Fluoroscopy-Guided Pericardiocentesis in Cardiac Tamponade. . 2025. PMID 40005382 · DOI · PMC11857578
- Labovitz AJ, Noble VE, Bierig M, Goldstein SA, Jones R, Kort S, et al.. Focused cardiac ultrasound in the emergent setting: a consensus statement of the American Society of Echocardiography and American College of Emergency Physicians. J Am Soc Echocardiogr. 2010. PMID 21111923 · DOI
- Akolekar R, Beta J, Picciarelli G, Ogilvie C, D'Antonio F. Procedure-related risk of miscarriage following amniocentesis and chorionic villus sampling: a systematic review and meta-analysis. Ultrasound Obstet Gynecol. 2015. PMID 25042845 · DOI
- Spodick DH. Acute cardiac tamponade. N Engl J Med. 2003. PMID 12917306 · DOI
- Salomon LJ, Sotiriadis A, Wulff CB, Odibo A, Akolekar R. Risk of miscarriage following amniocentesis or chorionic villus sampling: systematic review of literature and updated meta-analysis. Ultrasound Obstet Gynecol. 2019. PMID 31124209 · DOI
- American College of Obstetricians and Gynecologists. ACOG Practice Bulletin No. 88, December 2007. Invasive prenatal testing for aneuploidy. Obstet Gynecol. 2007. PMID 18055749 · DOI
- Gordon CE, Feller-Kopman D, Balk EM, Smetana GW. Pneumothorax following thoracentesis: a systematic review and meta-analysis. Arch Intern Med. 2010. PMID 20177035 · DOI
About this article
- Sources
- NLM Medical Subject Headings (definition, synonyms); NCBI PubMed (counts, identifiers); Europe PMC (open-access abstracts and citation counts).
- Verification
- Every reference was resolved against PubMed on 2026-11-04; title, year and DOI matched.
- Review state
- automated source verified; no human expert review has been recorded yet.
- Version
- 1, last updated 2026-11-04.
See how EvidenceLib is built. Spotted an error? Email support@evidencehelix.com.
Evidence strength
EvidenceHelix's computed view of the study designs behind this topic: how common meta-analyses, randomized trials and reviews are, how recent the literature is, and a plain-language reading. It describes the design mix of the literature. It is not a quality appraisal of any study, and it is not medical advice.