Cancer and Oncology182Genetics and Genomics170Neuroscience185Cardiovascular Medicine180Immunology142Pharmacology173Molecular Biology161Infectious Diseases150Rare and Inherited Diseases181Clinical Research173Anatomy and Physiology613Drugs and Chemicals621Psychiatry and Psychology185Public Health and Nutrition178Diagnostics and Medical Technology125Respiratory Medicine113Digestive System and Liver91Metabolism and Endocrine Disease177Bones, Joints, Muscles and Skin213Kidney, Urology and Women's Health173Eye, Ear, Nose and Throat55
Plans & pricingCompare EvidenceHelix workspace plans
Library›EvidenceLib›Diagnostics and Medical Technology›Oximetry

Continue where you left off ()

Explore more with EvidenceHelix Workspace

Compare studies, analyze evidence and create research reports with premium tools.

Explore Researcher plans

Research reading room

Oximetry

Diagnostics and Medical Technology · NLM MeSH · updated 2026-11-04 · version 1

Citations verified against PubMedNot yet clinician-reviewed10 referencesApproximately 6 min read

The determination of oxygen-hemoglobin saturation of blood either by withdrawing a sample and passing it through a classical photoelectric oximeter or by electrodes attached to some translucent part of the body like finger, earlob

Table of Contents

1. Definition2. Research landscape3. Reading the evidence4. Open-access studies5. Key reviews6. References7. About this article

Definition and research guide

This page combines a MeSH definition, publication statistics and selected research abstracts. It is a starting point for reading the literature, not a medical textbook or a systematic evidence review.

Content available: 4 complete abstracts (1,078 words), 10 references. Full article text is not stored or reproduced here; follow the PMID, DOI or PMC links to read the original sources and their access terms.

Definition

The determination of oxygen-hemoglobin saturation of blood either by withdrawing a sample and passing it through a classical photoelectric oximeter or by electrodes attached to some translucent part of the body like finger, earlobe, or skin fold. It includes non-invasive oxygen monitoring by pulse oximetry.

Definition: NLM Medical Subject Headings (MeSH) scope note (Public domain (U.S. National Library of Medicine); attribution requested). View the MeSH record.

Also known as: Oximetries; Oximetry, Pulse; Oximetries, Pulse; Pulse Oximetries; Pulse Oximetry.

Where it fits in the MeSH classification

Broader topics
Blood Gas Analysis; Heart Function Tests
Narrower topics
Blood Gas Monitoring, Transcutaneous

Research landscape

PubMed indexes 17,796 records tagged with the MeSH heading “Oximetry” (counts retrieved 2026-11-04). 2,656 of them (14.9%) were published from 2020 onward, and the busiest period so far is through 1999 with 6,346 records.

Reviews account for 1,489 records (8.4%) and meta-analyses for 96. Randomized controlled trials number 1,013 (5.7%) as a share of all records on the topic.

PubMed records by publication periodthrough 1999: 6,346 records; 2000-2009: 3,518 records; 2010-2019: 5,276 records; 2020 onward: 2,656 records6,346through 19993,5182000-20095,2762010-20192,6562020 onward
Records in PubMed indexed with this heading, by publication period. Real counts from NCBI E-utilities; the final period covers only part of the current year. Volume reflects how much has been published, not how strong the evidence is.
Show the data
PeriodRecords
through 19996,346
2000-20093,518
2010-20195,276
2020 onward2,656
Share of records by publication typeReviews: 8.4 percent; Meta-analyses: 0.5 percent; Randomized controlled trials: 5.7 percentReviews8.4% (1,489)Meta-analyses0.5% (96)Randomized controlled trials5.7% (1,013)
Share of all PubMed records on this heading that carry each publication type. Types overlap with other records, so the shares do not sum to 100%.
Publication-type chart data
Publication types among 17,796 PubMed records
TypeRecordsShare
Reviews1,4898.4%
Meta-analyses960.5%
Randomized controlled trials1,0135.7%

Method: PubMed query "Oximetry"[MeSH Terms] with publication-type and date filters, retrieved 2026-11-04.

Reading the evidence in diagnostics and medical technology

A test or device is judged by how well it detects a condition, how often it gives false alarms or misses cases, and whether using it improves outcomes for people. Accuracy depends on who is tested and how common the condition is, so a test that performs well in a specialist hospital can perform differently in the community. Check the reference standard, the population studied, the sensitivity and specificity and whether results were confirmed in a separate group.

Evidence from open-access studies

These open-access studies come from PubMed’s best-match results for this heading (papers whose main topic it is), ranked here by citation count, with one recent addition. Each abstract is reproduced in full under its recorded open licence so that you can read the authors’ own words. They illustrate the literature; they are not a systematic summary of it. Citation counts measure attention, not reliability or clinical benefit.

Study comparison — selected abstracts, not a systematic review
Study / authorsYearSource label / designEurope PMC citationsLicence / source
Beer-Lambert law for optical tissue diagnostics: current state of the art and the main limitations
Oshina I, Spigulis J
2021Review article
Design not recorded in structured metadata
95cc by
PMID 34713647 · DOI · PMC8553265
Muscle Oximetry in Sports Science: An Updated Systematic Review
Perrey S, Quaresima V, Ferrari M
2024Systematic review
Design not recorded in structured metadata
65cc by
PMID 38345731 · DOI · PMC11052892
Diagnostic Accuracy of Pulp Vitality Tests and Pulp Sensibility Tests for Assessing Pulpal Health in Permanent Teeth: A Systematic Review and Meta-Analysis
Patro S, Meto A, Mohanty A, Chopra V, Miglani S, Das A, et al.
2022Meta-analysis
Design not recorded in structured metadata
47cc by
PMID 35954958 · DOI · PMC9367848
Transcutaneous versus arterial carbon dioxide monitoring in adult polysomnography studies
Miller KA, Churchward TJ, Tolson J, Ruehland WR, McDonald CF, Worsnop CJ
2026Research article
Design not recorded in structured metadata
3cc by
PMID 40971476 · DOI · PMC13017198

Beer-Lambert law for optical tissue diagnostics: current state of the art and the main limitations [1]

Review article Oshina I, Spigulis J · · 2021 · cited 95 times (Europe PMC)

Abstract reading summary — source excerpts
Opening excerpt
SignificanceBeer-Lambert law (BLL) is a widely used tool for contact and remote determination of absorber concentration in various media, including living tissues.
Closing excerpt
Extended MBLL and BLL in the time domain form could provide more accurate results, but this requires more time resources to be spent.
Interpretation limits
Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (280 words)

SignificanceBeer-Lambert law (BLL) is a widely used tool for contact and remote determination of absorber concentration in various media, including living tissues. Originally proposed in the 18th century as a simple exponential expression, it has survived numerous modifications and updates. The basic assumptions of this law may not be fulfilled in real measurement conditions. This can lead to mistaken or misinterpreted results. In particular, the effects to be additionally taken into account in the tissue measurements include anisotropy, scattering, fluorescence, chemical equilibria, interference, dichroism, spectral bandwidth disagreements, stray radiation, and instrumental effects.AimWe review the current state of the art and the main limitations of remote tissue diagnostics using the BLL. Historical development of updating this law by taking into account specific additional factors such as light scattering and photon pathlengths in diffuse reflectance is described, along with highlighting the main risks to be considered by interpreting the measured data.ApproachLiterature data related to extension and modification of the BLL related to tissue assessment and concentration estimation of specific tissue molecules are collected and analyzed. The main emphasis here is put on the optical measurements of living tissue chromophore concentrations and estimation of physiological parameters, e.g., blood oxygen saturation.ResultsModified expressions of the BLL suitable for several specific cases of living tissue characterization are presented and discussed.ConclusionsApplications of updated/modified Beer-Lambert law (MBLL) with respect to particular measurement conditions are helpful for obtaining more reliable data on the target tissue physiological state and biochemical content. MBLL accounting for the role of scattering in several ways appears to be a successful approach. Extended MBLL and BLL in the time domain form could provide more accurate results, but this requires more time resources to be spent.

Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 34713647 · DOI · PMC8553265

Muscle Oximetry in Sports Science: An Updated Systematic Review [2]

Systematic review Perrey S, Quaresima V, Ferrari M · · 2024 · cited 65 times (Europe PMC)

Abstract reading summary — source excerpts
Opening excerpt
BackgroundIn the last 5 years since our last systematic review, a significant number of articles have been published on the technical aspects of muscle near-infrared spectroscopy (NIRS), the interpretation of the signals and the benefits of using the NIRS technique to measure the physiological status of muscles and to determine the workload of working muscles.
Closing excerpt
Longitudinal studies are urgently needed to strengthen the benefits of using muscle oximetry in sports science.
Interpretation limits
Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (324 words)

BackgroundIn the last 5 years since our last systematic review, a significant number of articles have been published on the technical aspects of muscle near-infrared spectroscopy (NIRS), the interpretation of the signals and the benefits of using the NIRS technique to measure the physiological status of muscles and to determine the workload of working muscles.ObjectivesConsidering the consistent number of studies on the application of muscle oximetry in sports science published over the last 5 years, the objectives of this updated systematic review were to highlight the applications of muscle oximetry in the assessment of skeletal muscle oxidative performance in sports activities and to emphasize how this technology has been applied to exercise and training over the last 5 years. In addition, some recent instrumental developments will be briefly summarized.MethodsPreferred Reporting Items for Systematic Reviews guidelines were followed in a systematic fashion to search, appraise and synthesize existing literature on this topic. Electronic databases such as Scopus, MEDLINE/PubMed and SPORTDiscus were searched from March 2017 up to March 2023. Potential inclusions were screened against eligibility criteria relating to recreationally trained to elite athletes, with or without training programmes, who must have assessed physiological variables monitored by commercial oximeters or NIRS instrumentation.ResultsOf the identified records, 191 studies regrouping 3435 participants, met the eligibility criteria. This systematic review highlighted a number of key findings in 37 domains of sport activities. Overall, NIRS information can be used as a meaningful marker of skeletal muscle oxidative capacity and can become one of the primary monitoring tools in practice in conjunction with, or in comparison with, heart rate or mechanical power indices in diverse exercise contexts and across different types of training and interventions.ConclusionsAlthough the feasibility and success of the use of muscle oximetry in sports science is well documented, there is still a need for further instrumental development to overcome current instrumental limitations. Longitudinal studies are urgently needed to strengthen the benefits of using muscle oximetry in sports science.

Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 38345731 · DOI · PMC11052892

Diagnostic Accuracy of Pulp Vitality Tests and Pulp Sensibility Tests for Assessing Pulpal Health in Permanent Teeth: A Systematic Review and Meta-Analysis [3]

Meta-analysis Patro S, Meto A, Mohanty A, Chopra V, Miglani S, Das A, et al. · · 2022 · cited 47 times (Europe PMC)

Abstract reading summary — source excerpts
Opening excerpt
The current systematic review and meta-analysis was carried out to compare the diagnostic accuracy of pulp vitality and pulp sensibility tests in assessing pulpal health.
Closing excerpt
This review provides information about the reliability and diagnostic accuracy of using pulp vitality and sensibility tests for assessing pulp status.
Interpretation limits
Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (249 words)

The current systematic review and meta-analysis was carried out to compare the diagnostic accuracy of pulp vitality and pulp sensibility tests in assessing pulpal health. PubMed/MEDLINE, Cochrane Central Register of Controlled Trials, Web of Science, Google Scholar and Open Grey databases were searched and after assessing eligibility criteria the data were extracted. True-positive, false-positive, true-negative, false-negative, sensitivity and specificity values were extracted or calculated if not presented. Quality of studies was evaluated based on the QUADAS 2 tool. Meta-analysis was performed in MetaDTA (v2.0; Shinyapps, RStudio PBC, Boston, MA, USA) and Review Manager 5.3 (RevMan web; The Cochrane Collaboration, London, UK). Ten articles were included for qualitative synthesis and five for meta-analysis. The pooled diagnostic odds ratio for pulse oximeter (PO), electric pulp tester (EPT), cold test (CT) and heat test (HT) was 628.5, 10.75, 17.24 and 3.47, respectively. Pairwise comparison demonstrated a higher pooled mean sensitivity and specificity with PO compared with EPT. Comparison between PO and CT and between PO and HT also demonstrated a higher pooled mean sensitivity and specificity for PO. Summary points on receiver operating characteristic curves confirmed the ability of PO to correctly screen negatives in presenting patients as compared to EPT, CT and HT but no study was rated as good on quality assessment. PO can be considered as the most accurate diagnostic method as compared to EPT, CT and HT. This review provides information about the reliability and diagnostic accuracy of using pulp vitality and sensibility tests for assessing pulp status.

Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 35954958 · DOI · PMC9367848

Transcutaneous versus arterial carbon dioxide monitoring in adult polysomnography studies [4]

Research article Miller KA, Churchward TJ, Tolson J, Ruehland WR, McDonald CF, Worsnop CJ · · 2026 · cited 3 times (Europe PMC)

Abstract reading summary — source excerpts
Opening excerpt
Study objectivesTo determine the accuracy of transcutaneous carbon dioxide measurements using SenTec tcPCO2 during adult polysomnography (PSG) compared to arterial PCO2.
Closing excerpt
ConclusionsThe SenTec tcPCO2 electrode was found to be an appropriate alternative to arterial sampling for assessment of arterial carbon dioxide in adult patients in the PSG setting, with no significant difference in tcPCO2 accuracy based on the timing of transcutaneous measurements (up to 2 min) following arterial sampling.
Interpretation limits
Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (225 words)

Study objectivesTo determine the accuracy of transcutaneous carbon dioxide measurements using SenTec tcPCO2 during adult polysomnography (PSG) compared to arterial PCO2.MethodsIn consecutive patients having PSG with transcutaneous CO2 (tcPCO2) monitoring using a SenTec monitor, arterial blood gas samples were taken at the beginning and at the end of each sleep study. tcPCO2 measurements recorded at 0, 60, and 120 s after arterial sampling was determined in 51 participants who underwent PSG with tcPCO2 monitoring at the Austin Health Sleep Laboratory (Heidelberg, VIC, Australia) during the period 01/05/22-10/06/22. The mean of differences between arterial carbon dioxide tension (PaCO2) and the predicted value based on tcPCO2 measurements determined at each time point for evening and morning arterial samples.ResultsData were obtained from 37 participants. A statistically significant difference in the tcPCO2 values at the point of arterial sampling was found, with tcPCO2 on average 2.2-2.8 mmHg less than PaCO2 at various timepoints after arterial sampling. The upper limit of measurement accuracy represented a moderate difference (2-4.9 mmHg), within the clinically acceptable range of -7.5 to +7.5 mmHg variation from PaCO2 values.ConclusionsThe SenTec tcPCO2 electrode was found to be an appropriate alternative to arterial sampling for assessment of arterial carbon dioxide in adult patients in the PSG setting, with no significant difference in tcPCO2 accuracy based on the timing of transcutaneous measurements (up to 2 min) following arterial sampling.

Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 40971476 · DOI · PMC13017198

Key reviews and meta-analyses

The most cited review-type papers among PubMed’s best-match results for this heading, listed with bibliographic details only. Follow the links for the full text and access terms.

  • Research article Pulse oximetry: understanding its basic principles facilitates appreciation of its limitations [5]
    Chan ED, Chan MM, Chan MM · Respir Med · 2013 · cited 363 times (Europe PMC)
  • Research article Monitoring tissue oxygenation by near infrared spectroscopy (NIRS): background and current applications [6]
    Scheeren TW, Schober P, Schwarte LA · J Clin Monit Comput · 2012 · cited 314 times (Europe PMC)
  • Research article Pulse oximetry [7]
    Jubran A · Crit Care · 2015 · cited 280 times (Europe PMC)
  • Research article Pulse oximetry screening for critical congenital heart defects in asymptomatic newborn babies: a systematic review and meta-analysis [8]
    Thangaratinam S, Brown K, Zamora J, Khan KS, Ewer AK · Lancet · 2012 · cited 237 times (Europe PMC)
  • Research article Overnight pulse oximetry for sleep-disordered breathing in adults: a review [9]
    Netzer N, Eliasson AH, Netzer C, Kristo DA · Chest · 2001 · cited 208 times (Europe PMC)
  • Research article Muscle Oximetry in Sports Science: A Systematic Review [10]
    Perrey S, Ferrari M · Sports Med · 2018 · cited 159 times (Europe PMC)

References

  1. Oshina I, Spigulis J. Beer-Lambert law for optical tissue diagnostics: current state of the art and the main limitations. . 2021. PMID 34713647 · DOI · PMC8553265
  2. Perrey S, Quaresima V, Ferrari M. Muscle Oximetry in Sports Science: An Updated Systematic Review. . 2024. PMID 38345731 · DOI · PMC11052892
  3. Patro S, Meto A, Mohanty A, Chopra V, Miglani S, Das A, et al.. Diagnostic Accuracy of Pulp Vitality Tests and Pulp Sensibility Tests for Assessing Pulpal Health in Permanent Teeth: A Systematic Review and Meta-Analysis. . 2022. PMID 35954958 · DOI · PMC9367848
  4. Miller KA, Churchward TJ, Tolson J, Ruehland WR, McDonald CF, Worsnop CJ. Transcutaneous versus arterial carbon dioxide monitoring in adult polysomnography studies. . 2026. PMID 40971476 · DOI · PMC13017198
  5. Chan ED, Chan MM, Chan MM. Pulse oximetry: understanding its basic principles facilitates appreciation of its limitations. Respir Med. 2013. PMID 23490227 · DOI
  6. Scheeren TW, Schober P, Schwarte LA. Monitoring tissue oxygenation by near infrared spectroscopy (NIRS): background and current applications. J Clin Monit Comput. 2012. PMID 22467064 · DOI · PMC3391360
  7. Jubran A. Pulse oximetry. Crit Care. 2015. PMID 26179876 · DOI · PMC4504215
  8. Thangaratinam S, Brown K, Zamora J, Khan KS, Ewer AK. Pulse oximetry screening for critical congenital heart defects in asymptomatic newborn babies: a systematic review and meta-analysis. Lancet. 2012. PMID 22554860 · DOI
  9. Netzer N, Eliasson AH, Netzer C, Kristo DA. Overnight pulse oximetry for sleep-disordered breathing in adults: a review. Chest. 2001. PMID 11502669 · DOI
  10. Perrey S, Ferrari M. Muscle Oximetry in Sports Science: A Systematic Review. Sports Med. 2018. PMID 29177977 · DOI

About this article

Sources
NLM Medical Subject Headings (definition, synonyms); NCBI PubMed (counts, identifiers); Europe PMC (open-access abstracts and citation counts).
Verification
Every reference was resolved against PubMed on 2026-11-04; title, year and DOI matched.
Review state
automated source verified; no human expert review has been recorded yet.
Version
1, last updated 2026-11-04.

See how EvidenceLib is built. Spotted an error? Email support@evidencehelix.com.

Evidence strength

EvidenceHelix's computed view of the study designs behind this topic: how common meta-analyses, randomized trials and reviews are, how recent the literature is, and a plain-language reading. It describes the design mix of the literature. It is not a quality appraisal of any study, and it is not medical advice.

Included with the Researcher plan

Reading every article stays free. This computed view is part of the paid plans.

See plans Sign in

Your notes

Notes and highlights stay in this browser only; they are not sent to EvidenceHelix.

Related research topics

  • Blood Urea NitrogenDiagnostics and Medical Technology
  • Continuous Glucose MonitoringDiagnostics and Medical Technology
  • Glucose Tolerance TestDiagnostics and Medical Technology
  • UrinalysisDiagnostics and Medical Technology
  • AortographyDiagnostics and Medical Technology
  • AutoradiographyDiagnostics and Medical Technology

All 110 articles in Diagnostics and Medical Technology →

At a glance

17,796
PubMed records on this heading
15%
published since 2020
1,489
review articles
1,013
randomized trials
10
verified references below

Counts come from PubMed on 2026-11-04; they show how much has been written, not how strong the evidence is.

Related topics See all →

  • Blood Urea NitrogenDiagnostics and Medical Technology
  • Continuous Glucose MonitoringDiagnostics and Medical Technology
  • Glucose Tolerance TestDiagnostics and Medical Technology
  • UrinalysisDiagnostics and Medical Technology
  • AortographyDiagnostics and Medical Technology

My notes & annotations (0)

Nothing yet. Select text and press Highlight, or write a note in the Notes tab. Stored in this browser only.

Sources

  • NLM MeSH record ↗
  • PubMed search used ↗

EvidenceLib is a research-education resource, not medical advice. It does not diagnose, prescribe or recommend starting, stopping or changing any treatment. Talk to a qualified clinician about your own situation. Methods, sources and licences · Rights and removal requests · Legal · Support