Skip to content
EvidenceHelixEvidenceLib · Scientific Encyclopedia
⌘ K

Scientific library

EvidenceLib encyclopediaAll articles A–Z2,835Open textbooks209Open-access articles1,406Cancer study catalog458How it is made

My workspace this browser

Saved pages0Notes & annotations0

Recently viewed

Explore by field

Cancer and Oncology182Genetics and Genomics170Neuroscience185Cardiovascular Medicine180Immunology142Pharmacology173Molecular Biology161Infectious Diseases150Rare and Inherited Diseases181Clinical Research173Anatomy and Physiology613Drugs and Chemicals621Psychiatry and Psychology185Public Health and Nutrition178Diagnostics and Medical Technology125Respiratory Medicine113Digestive System and Liver91Metabolism and Endocrine Disease177Bones, Joints, Muscles and Skin213Kidney, Urology and Women's Health173Eye, Ear, Nose and Throat55
Plans & pricingCompare EvidenceHelix workspace plans
Library›EvidenceLib›Diagnostics and Medical Technology›International Normalized Ratio

Continue where you left off ()

Explore more with EvidenceHelix Workspace

Compare studies, analyze evidence and create research reports with premium tools.

Explore Researcher plans

Research reading room

International Normalized Ratio

Diagnostics and Medical Technology · NLM MeSH · updated 2026-11-04 · version 1

Citations verified against PubMedNot yet clinician-reviewed10 referencesApproximately 4 min read

System established by the World Health Organization and the International Committee on Thrombosis and Hemostasis for monitoring and reporting blood coagulation tests.

Table of Contents

1. Definition2. Research landscape3. Reading the evidence4. Open-access studies5. Key reviews6. References7. About this article

Definition and research guide

This page combines a MeSH definition, publication statistics and selected research abstracts. It is a starting point for reading the literature, not a medical textbook or a systematic evidence review.

Content available: 4 complete abstracts (810 words), 10 references. Full article text is not stored or reproduced here; follow the PMID, DOI or PMC links to read the original sources and their access terms.

Definition

System established by the World Health Organization and the International Committee on Thrombosis and Hemostasis for monitoring and reporting blood coagulation tests. Under this system, results are standardized using the International Sensitivity Index for the particular test reagent/instrument combination used.

Definition: NLM Medical Subject Headings (MeSH) scope note (Public domain (U.S. National Library of Medicine); attribution requested). View the MeSH record.

Also known as: International Normalized Ratios; Normalized Ratio, International; Normalized Ratios, International; Ratio, International Normalized; Ratios, International Normalized; INR.

Where it fits in the MeSH classification

Broader topics
Blood Coagulation Tests
See also
Blood Coagulation

Research landscape

PubMed indexes 6,472 records tagged with the MeSH heading “International Normalized Ratio” (counts retrieved 2026-11-04). 953 of them (14.7%) were published from 2020 onward, and the busiest period so far is 2010-2019 with 3,225 records.

Reviews account for 681 records (10.5%) and meta-analyses for 98. Randomized controlled trials number 482 (7.4%) as a share of all records on the topic.

PubMed records by publication periodthrough 1999: 138 records; 2000-2009: 2,156 records; 2010-2019: 3,225 records; 2020 onward: 953 records138through 19992,1562000-20093,2252010-20199532020 onward
Records in PubMed indexed with this heading, by publication period. Real counts from NCBI E-utilities; the final period covers only part of the current year. Volume reflects how much has been published, not how strong the evidence is.
Show the data
PeriodRecords
through 1999138
2000-20092,156
2010-20193,225
2020 onward953
Share of records by publication typeReviews: 10.5 percent; Meta-analyses: 1.5 percent; Randomized controlled trials: 7.4 percentReviews10.5% (681)Meta-analyses1.5% (98)Randomized controlled trials7.4% (482)
Share of all PubMed records on this heading that carry each publication type. Types overlap with other records, so the shares do not sum to 100%.
Publication-type chart data
Publication types among 6,472 PubMed records
TypeRecordsShare
Reviews68110.5%
Meta-analyses981.5%
Randomized controlled trials4827.4%

Method: PubMed query "International Normalized Ratio"[MeSH Terms] with publication-type and date filters, retrieved 2026-11-04.

Reading the evidence in diagnostics and medical technology

A test or device is judged by how well it detects a condition, how often it gives false alarms or misses cases, and whether using it improves outcomes for people. Accuracy depends on who is tested and how common the condition is, so a test that performs well in a specialist hospital can perform differently in the community. Check the reference standard, the population studied, the sensitivity and specificity and whether results were confirmed in a separate group.

Evidence from open-access studies

These open-access studies come from PubMed’s best-match results for this heading (papers whose main topic it is), ranked here by citation count, with one recent addition. Each abstract is reproduced in full under its recorded open licence so that you can read the authors’ own words. They illustrate the literature; they are not a systematic summary of it. Citation counts measure attention, not reliability or clinical benefit.

Study comparison — selected abstracts, not a systematic review
Study / authorsYearSource label / designEurope PMC citationsLicence / source
Fixed Versus Variable Dosing of Prothrombin Complex Concentrate in Vitamin K Antagonist-Related Intracranial Hemorrhage: A Retrospective Analysis
Abdoellakhan RA, Miah IP, Khorsand N, Meijer K, Jellema K
2017Research article
Design not recorded in structured metadata
34cc by
PMID 27052728 · DOI · PMC5226998
Center-Related Determinants of VKA Anticoagulation Quality: A Prospective, Multicenter Evaluation
Tosetto A, Manotti C, Marongiu F, Italian Federation of Anticoagulation Clinics (FCSA) clinical quality study group
2015Research article
Design not recorded in structured metadata
17cc by
PMID 26636337 · DOI · PMC4670074
Micro-mechanical blood clot testing using smartphones
Chan J, Michaelsen K, Estergreen JK, Sabath DE, Gollakota S
2022Research article
Design not recorded in structured metadata
16cc by
PMID 35149711 · DOI · PMC8837659
In vitro Study of the Effects of Acetylcysteine on the International Normalized Ratio Over Time
Nazar M, Kootstra-Ros JE, Touw DJ, Sturkenboom MGG
2026Research article
Design not recorded in structured metadata
0cc by
PMID 40663728 · DOI · PMC13152081

Fixed Versus Variable Dosing of Prothrombin Complex Concentrate in Vitamin K Antagonist-Related Intracranial Hemorrhage: A Retrospective Analysis [1]

Research article Abdoellakhan RA, Miah IP, Khorsand N, Meijer K, Jellema K · · 2017 · cited 34 times (Europe PMC)

Abstract reading summary — source excerpts
Opening excerpt
BackgroundMillions of patients receive vitamin K antagonist (VKA) therapy worldwide.
Closing excerpt
The effect on clinical outcome remains unknown.
Interpretation limits
Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (259 words)

BackgroundMillions of patients receive vitamin K antagonist (VKA) therapy worldwide. Annually 0.2-1 % of all VKA users develops an intracranial hemorrhage (ICH). Prothrombin complex concentrate (PCC) is administered to restore the INR ≤ 1.5 in an attempt to limit hematoma growth. In order to facilitate PCC dosing, our hospital recently changed from a variable dose based on bodyweight, baseline- and target-INR, to a fixed 1000 IU fIX PCC dosing protocol for ICH.MethodsIn a before and after design, we compared successful achievement of an INR ≤ 1.5 with a fixed dosing strategy versus the variable dosing strategy of PCC in patients presenting with intracranial bleeding complications of VKA. Data of the two cohorts of patients were retrospectively collected from medical records.ResultsA median dosage of 1750 IU was given per patient in the variable dose group (n = 25) versus 1000 IU in the fixed dose group (n = 28). In the intention-to-treat analysis, 96 % achieved an INR ≤ 1.5 after an initial dose in the variable dose cohort compared to 68 % in the fixed dose cohort (p = 0.01). An additional dose was given in 2 (8 %) versus 9 (32 %) patients, respectively (p = 0.04). The median door-to-PCC-order time was 42 versus 32 min (p = 0.37) and the door-to-needle time was 81, respectively 60 min (p = 0.42).ConclusionThe fixed dose protocol necessitates additional PCC infusions more frequently to achieve a target INR ≤ 1.5. Door-to-order and door-to-needle time were shorter but, in this small cohort, not significantly so. The effect on clinical outcome remains unknown.

Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 27052728 · DOI · PMC5226998

Center-Related Determinants of VKA Anticoagulation Quality: A Prospective, Multicenter Evaluation [2]

Research article Tosetto A, Manotti C, Marongiu F, Italian Federation of Anticoagulation Clinics (FCSA) clinical quality study group · · 2015 · cited 17 times (Europe PMC)

Abstract reading summary — source excerpts
Opening excerpt
BackgroundCenter-specific TTR (c-TTR) is a measure reporting the mean patient TTR within an anticoagulation clinic describing the quality of anticoagulant monitoring offered by that clinic.
Closing excerpt
ConclusionsThese findings suggest that c-TTR associates with proactive strategies aimed at keeping patients very close to their target INR with a prompt re-evaluation of those patients with under- or over-therapeutic INR.
Interpretation limits
Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (208 words)

BackgroundCenter-specific TTR (c-TTR) is a measure reporting the mean patient TTR within an anticoagulation clinic describing the quality of anticoagulant monitoring offered by that clinic. c-TTR has a considerable between-center variation, but its determinants are poorly understood.ObjectivesWe aimed at evaluating which clinical, procedural or laboratory factors could be associated with c-TTR variability in a multicenter, observational cross-sectional study over a five-year period.Patients/methodsData from 832,204 individual patients followed for VKA therapy in 292 Centers affiliated with the Italian Federation of Anticoagulation Clinics (FCSA) were analyzed. c-TTR was computed based on the TTR of patients followed at each Center, and a mixed linear regression model was used for a predefined set of explanatory variables.ResultsThe Center next-visit interval ratio (the mean number of days after a visit with an INR outside the therapeutic range, divided by the days after a visit with an INR within the therapeutic range), the Center mean patient INR and the Center laboratory performance at EQA proficiency testing were the only variables that were independently associated with c-TTR (β-coefficients -17.32, 9.67, and -0.11, respectively; r2 = 0.635).ConclusionsThese findings suggest that c-TTR associates with proactive strategies aimed at keeping patients very close to their target INR with a prompt re-evaluation of those patients with under- or over-therapeutic INR.

Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 26636337 · DOI · PMC4670074

Micro-mechanical blood clot testing using smartphones [3]

Research article Chan J, Michaelsen K, Estergreen JK, Sabath DE, Gollakota S · · 2022 · cited 16 times (Europe PMC)

Abstract reading summary — source excerpts
Opening excerpt
Frequent prothrombin time (PT) and international normalized ratio (INR) testing is critical for millions of people on lifelong anticoagulation with warfarin.
Closing excerpt
Given the ubiquity of smartphones in the global setting, this proof-of-concept technology may provide affordable and effective PT and INR testing in low-resource environments.
Interpretation limits
Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (150 words)

Frequent prothrombin time (PT) and international normalized ratio (INR) testing is critical for millions of people on lifelong anticoagulation with warfarin. Currently, testing is performed in hospital laboratories or with expensive point-of-care devices limiting the ability to test frequently and affordably. We report a proof-of-concept PT/INR testing system that uses the vibration motor and camera on smartphones to track micro-mechanical movements of a copper particle. The smartphone system computed the PT/INR with inter-class correlation coefficients of 0.963 and 0.966, compared to a clinical-grade coagulation analyzer for 140 plasma samples and demonstrated similar results for 80 whole blood samples using a single drop of blood (10 μl). When tested with 79 blood samples with coagulopathic conditions, the smartphone system demonstrated a correlation of 0.974 for both PT/INR. Given the ubiquity of smartphones in the global setting, this proof-of-concept technology may provide affordable and effective PT and INR testing in low-resource environments.

Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 35149711 · DOI · PMC8837659

In vitro Study of the Effects of Acetylcysteine on the International Normalized Ratio Over Time [4]

Research article Nazar M, Kootstra-Ros JE, Touw DJ, Sturkenboom MGG · · 2026

Abstract reading summary — source excerpts
Opening excerpt
BackgroundPatients with paracetamol poisoning are treated with acetylcysteine.
Closing excerpt
Additionally, a large interindividual variability was observed.
Interpretation limits
Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (193 words)

BackgroundPatients with paracetamol poisoning are treated with acetylcysteine. In paracetamol-poisoned patients without hepatocellular injury, an increased international normalized ratio (INR) was observed after acetylcysteine administration. Because INR is a marker of liver injury in paracetamol poisoning, assessing the magnitude of the effect of acetylcysteine treatment on INR is crucial. This in vitro study aimed to quantify the effects of clinically relevant concentrations of acetylcysteine on INR over time.MethodsAcetylcysteine (0-500 mg/L) in Omniplasma (pooled plasma) or citrate plasma from 6 healthy subjects was incubated at 37°C for up to 24 or 6 hours, respectively. Combined with acetylcysteine, the effects of paracetamol (0-200 mg/L), incubation temperature (37, 20, and 4°C), and tube size (15 and 2.5 mL) were investigated. Samples were drawn frequently and analyzed for INR. Citrate plasma from healthy subjects was used to assess interindividual variability. Data were analyzed using a generalized linear mixed model.ResultsAt 37°C, every mmol/L (equals 163 mg/L) of acetylcysteine increased the INR with 0.039 (99% confidence interval [CI] 0.032-0.046, P ConclusionsThis in vitro study showed a clinically significant effect of increasing acetylcysteine concentrations on INR over time at 37°C in pooled plasma. Additionally, a large interindividual variability was observed.

Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 40663728 · DOI · PMC13152081

Key reviews and meta-analyses

The most cited review-type papers among PubMed’s best-match results for this heading, listed with bibliographic details only. Follow the links for the full text and access terms.

  • Research article How to interpret and pursue an abnormal prothrombin time, activated partial thromboplastin time, and bleeding time in adults [5]
    Kamal AH, Tefferi A, Pruthi RK · Mayo Clin Proc · 2007 · cited 234 times (Europe PMC)
  • Research article Review article: the prothrombin time test as a measure of bleeding risk and prognosis in liver disease [6]
    Tripodi A, Caldwell SH, Hoffman M, Trotter JF, Sanyal AJ · Aliment Pharmacol Ther · 2007 · cited 141 times (Europe PMC)
  • Research article Optimal INR for prevention of stroke and death in atrial fibrillation: a critical appraisal [7]
    Odén A, Fahlén M, Hart RG · Thromb Res · 2006 · cited 103 times (Europe PMC)
  • Research article Standardization of Prothrombin Time/International Normalized Ratio (PT/INR) [8]
    Dorgalaleh A, Favaloro EJ, Bahraini M, Rad F · Int J Lab Hematol · 2021 · cited 88 times (Europe PMC)
  • Research article Precision and accuracy of point-of-care testing coagulometers used for self-testing and self-management of oral anticoagulation therapy [9]
    Christensen TD, Larsen TB · J Thromb Haemost · 2012 · cited 67 times (Europe PMC)
  • Research article Guidelines on preparation, certification, and use of certified plasmas for ISI calibration and INR determination [10]
    van den Besselaar AM, Barrowcliffe TW, Houbouyan-Réveillard LL, Jespersen J, Johnston M, Poller L, et al. · J Thromb Haemost · 2004 · cited 59 times (Europe PMC)

References

  1. Abdoellakhan RA, Miah IP, Khorsand N, Meijer K, Jellema K. Fixed Versus Variable Dosing of Prothrombin Complex Concentrate in Vitamin K Antagonist-Related Intracranial Hemorrhage: A Retrospective Analysis. . 2017. PMID 27052728 · DOI · PMC5226998
  2. Tosetto A, Manotti C, Marongiu F, Italian Federation of Anticoagulation Clinics (FCSA) clinical quality study group. Center-Related Determinants of VKA Anticoagulation Quality: A Prospective, Multicenter Evaluation. . 2015. PMID 26636337 · DOI · PMC4670074
  3. Chan J, Michaelsen K, Estergreen JK, Sabath DE, Gollakota S. Micro-mechanical blood clot testing using smartphones. . 2022. PMID 35149711 · DOI · PMC8837659
  4. Nazar M, Kootstra-Ros JE, Touw DJ, Sturkenboom MGG. In vitro Study of the Effects of Acetylcysteine on the International Normalized Ratio Over Time. . 2026. PMID 40663728 · DOI · PMC13152081
  5. Kamal AH, Tefferi A, Pruthi RK. How to interpret and pursue an abnormal prothrombin time, activated partial thromboplastin time, and bleeding time in adults. Mayo Clin Proc. 2007. PMID 17605969 · DOI
  6. Tripodi A, Caldwell SH, Hoffman M, Trotter JF, Sanyal AJ. Review article: the prothrombin time test as a measure of bleeding risk and prognosis in liver disease. Aliment Pharmacol Ther. 2007. PMID 17593061 · DOI
  7. Odén A, Fahlén M, Hart RG. Optimal INR for prevention of stroke and death in atrial fibrillation: a critical appraisal. Thromb Res. 2006. PMID 16517250 · DOI
  8. Dorgalaleh A, Favaloro EJ, Bahraini M, Rad F. Standardization of Prothrombin Time/International Normalized Ratio (PT/INR). Int J Lab Hematol. 2021. PMID 32979036 · DOI
  9. Christensen TD, Larsen TB. Precision and accuracy of point-of-care testing coagulometers used for self-testing and self-management of oral anticoagulation therapy. J Thromb Haemost. 2012. PMID 22118602 · DOI
  10. van den Besselaar AM, Barrowcliffe TW, Houbouyan-Réveillard LL, Jespersen J, Johnston M, Poller L, et al.. Guidelines on preparation, certification, and use of certified plasmas for ISI calibration and INR determination. J Thromb Haemost. 2004. PMID 15550026 · DOI

About this article

Sources
NLM Medical Subject Headings (definition, synonyms); NCBI PubMed (counts, identifiers); Europe PMC (open-access abstracts and citation counts).
Verification
Every reference was resolved against PubMed on 2026-11-04; title, year and DOI matched.
Review state
automated source verified; no human expert review has been recorded yet.
Version
1, last updated 2026-11-04.

See how EvidenceLib is built. Spotted an error? Email support@evidencehelix.com.

Evidence strength

EvidenceHelix's computed view of the study designs behind this topic: how common meta-analyses, randomized trials and reviews are, how recent the literature is, and a plain-language reading. It describes the design mix of the literature. It is not a quality appraisal of any study, and it is not medical advice.

Included with the Researcher plan

Reading every article stays free. This computed view is part of the paid plans.

See plans Sign in

Your notes

Notes and highlights stay in this browser only; they are not sent to EvidenceHelix.

Related research topics

  • CD4-CD8 RatioImmunology
  • Bleeding TimeAnatomy and Physiology
  • Blood Cell CountMolecular Biology
  • HematocritAnatomy and Physiology
  • Leukocyte CountMolecular Biology
  • Partial Thromboplastin TimeAnatomy and Physiology

All 110 articles in Diagnostics and Medical Technology →

At a glance

6,472
PubMed records on this heading
15%
published since 2020
681
review articles
482
randomized trials
10
verified references below

Counts come from PubMed on 2026-11-04; they show how much has been written, not how strong the evidence is.

Related topics See all →

  • CD4-CD8 RatioImmunology
  • Bleeding TimeAnatomy and Physiology
  • Blood Cell CountMolecular Biology
  • HematocritAnatomy and Physiology
  • Leukocyte CountMolecular Biology

My notes & annotations (0)

Nothing yet. Select text and press Highlight, or write a note in the Notes tab. Stored in this browser only.

Sources

  • NLM MeSH record ↗
  • PubMed search used ↗

EvidenceLib is a research-education resource, not medical advice. It does not diagnose, prescribe or recommend starting, stopping or changing any treatment. Talk to a qualified clinician about your own situation. Methods, sources and licences · Rights and removal requests · Legal · Support