Skip to content
EvidenceHelixEvidenceLib · Scientific Encyclopedia
⌘ K

Scientific library

EvidenceLib encyclopediaAll articles A–Z2,835Open textbooks209Open-access articles1,406Cancer study catalog458How it is made

My workspace this browser

Saved pages0Notes & annotations0

Recently viewed

Explore by field

Cancer and Oncology182Genetics and Genomics170Neuroscience185Cardiovascular Medicine180Immunology142Pharmacology173Molecular Biology161Infectious Diseases150Rare and Inherited Diseases181Clinical Research173Anatomy and Physiology613Drugs and Chemicals621Psychiatry and Psychology185Public Health and Nutrition178Diagnostics and Medical Technology125Respiratory Medicine113Digestive System and Liver91Metabolism and Endocrine Disease177Bones, Joints, Muscles and Skin213Kidney, Urology and Women's Health173Eye, Ear, Nose and Throat55
Plans & pricingCompare EvidenceHelix workspace plans
Library›EvidenceLib›Diagnostics and Medical Technology›Crowns

Continue where you left off ()

Explore more with EvidenceHelix Workspace

Compare studies, analyze evidence and create research reports with premium tools.

Explore Researcher plans

Research reading room

Crowns

Diagnostics and Medical Technology · NLM MeSH · updated 2026-11-04 · version 1

Citations verified against PubMedNot yet clinician-reviewed10 referencesApproximately 5 min read

A prosthetic restoration that reproduces the entire surface anatomy of the visible natural crown of a tooth.

Table of Contents

1. Definition2. Research landscape3. Reading the evidence4. Open-access studies5. Key reviews6. References7. About this article

Definition and research guide

This page combines a MeSH definition, publication statistics and selected research abstracts. It is a starting point for reading the literature, not a medical textbook or a systematic evidence review.

Content available: 4 complete abstracts (959 words), 10 references. Full article text is not stored or reproduced here; follow the PMID, DOI or PMC links to read the original sources and their access terms.

Definition

A prosthetic restoration that reproduces the entire surface anatomy of the visible natural crown of a tooth. It may be partial (covering three or more surfaces of a tooth) or complete (covering all surfaces). It is made of gold or other metal, porcelain, or resin.

Definition: NLM Medical Subject Headings (MeSH) scope note (Public domain (U.S. National Library of Medicine); attribution requested). View the MeSH record.

Also known as: Crown; Crown, Dental; Crowns, Dental; Dental Crown; Dental Crowns.

Where it fits in the MeSH classification

Broader topics
Dental Prosthesis
Narrower topics
Post and Core Technique
See also
Dental Porcelain

Research landscape

PubMed indexes 22,070 records tagged with the MeSH heading “Crowns” (counts retrieved 2026-11-04). 3,484 of them (15.8%) were published from 2020 onward, and the busiest period so far is through 1999 with 9,826 records.

Reviews account for 1,022 records (4.6%) and meta-analyses for 153. Randomized controlled trials number 970 (4.4%) as a share of all records on the topic.

PubMed records by publication periodthrough 1999: 9,826 records; 2000-2009: 3,789 records; 2010-2019: 4,971 records; 2020 onward: 3,484 records9,826through 19993,7892000-20094,9712010-20193,4842020 onward
Records in PubMed indexed with this heading, by publication period. Real counts from NCBI E-utilities; the final period covers only part of the current year. Volume reflects how much has been published, not how strong the evidence is.
Show the data
PeriodRecords
through 19999,826
2000-20093,789
2010-20194,971
2020 onward3,484
Share of records by publication typeReviews: 4.6 percent; Meta-analyses: 0.7 percent; Randomized controlled trials: 4.4 percentReviews4.6% (1,022)Meta-analyses0.7% (153)Randomized controlled trials4.4% (970)
Share of all PubMed records on this heading that carry each publication type. Types overlap with other records, so the shares do not sum to 100%.
Publication-type chart data
Publication types among 22,070 PubMed records
TypeRecordsShare
Reviews1,0224.6%
Meta-analyses1530.7%
Randomized controlled trials9704.4%

Method: PubMed query "Crowns"[MeSH Terms] with publication-type and date filters, retrieved 2026-11-04.

Reading the evidence in diagnostics and medical technology

A test or device is judged by how well it detects a condition, how often it gives false alarms or misses cases, and whether using it improves outcomes for people. Accuracy depends on who is tested and how common the condition is, so a test that performs well in a specialist hospital can perform differently in the community. Check the reference standard, the population studied, the sensitivity and specificity and whether results were confirmed in a separate group.

Evidence from open-access studies

These open-access studies come from PubMed’s best-match results for this heading (papers whose main topic it is), ranked here by citation count, with one recent addition. Each abstract is reproduced in full under its recorded open licence so that you can read the authors’ own words. They illustrate the literature; they are not a systematic summary of it. Citation counts measure attention, not reliability or clinical benefit.

Study comparison — selected abstracts, not a systematic review
Study / authorsYearSource label / designEurope PMC citationsLicence / source
Static and dynamic stress analysis of different crown materials on a titanium base abutment in an implant-supported single crown: a 3D finite element analysis
Deste Gökay G, Oyar P, Gökçimen G, Durkan R
2024Research article
Design not recorded in structured metadata
18cc by
PMID 38730391 · DOI · PMC11088090
Comparative evaluation of clinical performance, child and parental satisfaction of Bioflx, zirconia and stainless steel crowns in pediatric patients
Rahate I, Fulzele P, Thosar N
2023Research article
Design not recorded in structured metadata
17cc by
PMID 38911945 · DOI · PMC11190641
Convex Versus Concave Emergence Profile of Implant-Supported Crowns in the Aesthetic Zone: 3-Year Results of a Randomized Controlled Trial
Endres J, Strauss FJ, Siegenthaler M, Naenni N, Jung RE, Thoma DS
2025Randomized controlled trial
Design not recorded in structured metadata
12cc by
PMID 40836504 · DOI · PMC12531365
A Review of Current Systems, Materials, and Protocols for 3D-Printed Splints, Crowns, and Dentures
Sabanik P, Liu TC, Tabatabaeian M, Rocha MG, Surathu N, Lawson NC
2026Review article
Design not recorded in structured metadata
7cc by
PMID 41700503 · DOI · PMC13062704

Static and dynamic stress analysis of different crown materials on a titanium base abutment in an implant-supported single crown: a 3D finite element analysis [1]

Research article Deste Gökay G, Oyar P, Gökçimen G, Durkan R · · 2024 · cited 18 times (Europe PMC)

Abstract reading summary — source excerpts
Opening excerpt
BackgroundThis Finite Element Analysis was conducted to analyze the biomechanical behaviors of titanium base abutments and several crown materials with respect to fatigue lifetime and stress distribution in implants and prosthetic components.
Closing excerpt
ConclusionsWith the promise of at least ten years of clinical success and favorable stress distributions in implants and prosthetic components, clinicians can suggest using an implant-supported lithium disilicate crown with a titanium base abutment.
Interpretation limits
Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (255 words)

BackgroundThis Finite Element Analysis was conducted to analyze the biomechanical behaviors of titanium base abutments and several crown materials with respect to fatigue lifetime and stress distribution in implants and prosthetic components.MethodsFive distinct designs of implant-supported single crowns were modeled, including a polyetheretherketone (PEEK), polymer-infiltrated ceramic network, monolithic lithium disilicate, and precrystallized and crystallized zirconia-reinforced lithium silicates supported by a titanium base abutment. For the static load, a 100 N oblique load was applied to the buccal incline of the palatal cusp of the maxillary right first premolar. The dynamic load was applied in the same way as in static loading with a frequency of 1 Hz. The principal stresses in the peripheral bone as well as the von Mises stresses and fatigue strength of the implants, abutments, prosthetic screws, and crowns were assessed.ResultsAll of the models had comparable von Mises stress values from the implants and abutments, as well as comparable maximum and minimum principal stress values from the cortical and trabecular bones. The PEEK crown showed the lowest stress (46.89 MPa) in the cervical region. The prosthetic screws and implants exhibited the highest von Mises stress among the models. The lithium disilicate crown model had approximately 9.5 times more cycles to fatique values for implants and 1.7 times more cycles to fatique values for abutments than for the lowest ones.ConclusionsWith the promise of at least ten years of clinical success and favorable stress distributions in implants and prosthetic components, clinicians can suggest using an implant-supported lithium disilicate crown with a titanium base abutment.

Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 38730391 · DOI · PMC11088090

Comparative evaluation of clinical performance, child and parental satisfaction of Bioflx, zirconia and stainless steel crowns in pediatric patients [2]

Research article Rahate I, Fulzele P, Thosar N · · 2023 · cited 17 times (Europe PMC)

Abstract reading summary — source excerpts
Opening excerpt
BackgroundPediatric dental treatment is challenging in patients with early childhood caries.
Closing excerpt
Protocol versionTwo; Date: April 22, 2023.
Interpretation limits
Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (218 words)

BackgroundPediatric dental treatment is challenging in patients with early childhood caries. For clinician its difficult to manage child and provide good work at the same time. Its necessity to have the best equipments as well as materials. Nowadays, aesthetics play an important role in managing decayed teeth. Zirconia crown is better option but requires excessive preparation. As Bioflx is newly developed crown and has combined stainless steel and zirconia properties.AimTo assess the clinical performance and child and parental satisfaction of Bioflex crowns compared to zirconia and stainless steel crowns.MethodsIn this comparative study of Bioflx crowns with zirconia and stainless steel crowns, children aged three to seven years old will be selected, and 72 primary teeth requiring crowns will be randomly distributed into three groups, n = 24: Group I: Preformed stainless steel crown, control; Group II: Preformed Bioflex crown; Group III: Preformed zirconia crown. Crowns will be evaluated for recurrent caries, plaque accumulation, restoration failure, gingival status opposing tooth wear, and clinicians and parental satisfaction at zero, three, six, and 12 months.ResultsBioflx crown will have better clinical as well as parental satisfaction among zirconia and stainless steel crowns.ConclusionsThe Bioflx crown can be used as an alternative economical esthetic full-coronal restoration for primary teeth.Trial registrationCTRI registration number: CTRI/2023/05/052256; Date of registration: May 03, 2023.Protocol versionTwo; Date: April 22, 2023.

Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 38911945 · DOI · PMC11190641

Convex Versus Concave Emergence Profile of Implant-Supported Crowns in the Aesthetic Zone: 3-Year Results of a Randomized Controlled Trial [3]

Randomized controlled trial Endres J, Strauss FJ, Siegenthaler M, Naenni N, Jung RE, Thoma DS · · 2025 · cited 12 times (Europe PMC)

Abstract reading summary — source excerpts
Opening excerpt
AimTo evaluate the 3-year clinical and radiographic outcomes of implant-supported restorations with different emergence profiles (CONVEX vs.
Closing excerpt
Trial registrationGerman Clinical Trials Register: DRKS00009420.
Interpretation limits
Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (285 words)

AimTo evaluate the 3-year clinical and radiographic outcomes of implant-supported restorations with different emergence profiles (CONVEX vs. CONCAVE).Materials and methodsA total of 47 patients received a single implant in the aesthetic zone and were allocated to one of three groups: (1) CONVEX: customized provisional with a convex emergence profile (n = 15); (2) CONCAVE: customized provisional with a concave profile (n = 16); (3) Control: no provisional restoration (n = 16). Final crowns in groups CONVEX and CONCAVE were fabricated to replicate the emergence profile of the respective provisional restorations. Follow-ups were performed at baseline, 6 months, 1 year and 3 years. The primary outcome was mid-facial mucosal recession and secondary outcomes included clinical, radiographic and aesthetic outcomes as well as profilometric measurements. Multivariable logistic regressions and mixed-effects models were used to compare the groups.ResultsOut of the 47 patients originally included, 42 were available for re-examination at 3 years follow-up. At 3 years, the frequency of mucosal recession amounted to 46.7% in group CONVEX, 13.3% in group CONCAVE and 40.0% in group Control. Adjusted logistic regression models revealed that the CONVEX group was significantly more likely to show recessions at 3 years (odds ratios [ORs]: 7.3, 95% CI: 1.02-52.14, p = 0.048) when compared with the CONCAVE group. No statistically significant difference in recession frequency was observed between the CONVEX and CONCAVE groups between the 1- and 3-year follow-ups (OR: 3.7, 95% CI: 0.30-46.09, p = 0.303).ConclusionThe emergence profile design significantly influences soft tissue stability predominantly within the first year after crown insertion. Whenever clinically feasible, a CONCAVE profile is preferable in the aesthetic zone to maintain the level of the mid-facial mucosal margin and reduce the frequency of recessions.Trial registrationGerman Clinical Trials Register: DRKS00009420.

Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 40836504 · DOI · PMC12531365

A Review of Current Systems, Materials, and Protocols for 3D-Printed Splints, Crowns, and Dentures [4]

Review article Sabanik P, Liu TC, Tabatabaeian M, Rocha MG, Surathu N, Lawson NC · · 2026 · cited 7 times (Europe PMC)

Abstract reading summary — source excerpts
Opening excerpt
ObjectivesTo summarize and synthesize evidence-based conclusions on optimal three-dimensional (3D) printing technologies, materials, and clinical protocols for splints, crowns, and dentures.
Closing excerpt
Clinical significanceEmploying validated printing parameters, selecting the appropriate resin, and following evidence-based protocols allows clinicians to maximize restoration accuracy and mechanical performance while leveraging 3D printing's efficiency and cost benefits.
Interpretation limits
Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (201 words)

ObjectivesTo summarize and synthesize evidence-based conclusions on optimal three-dimensional (3D) printing technologies, materials, and clinical protocols for splints, crowns, and dentures.OverviewIn resin vat printing, stereolithography (SLA) offers superior surface finish, while liquid crystal display (LCD) and digital light processing (DLP) excel in speed for larger prints, with LCD providing a cost advantage. Ceramic vat printing yields clinically acceptable strength but is equipment- and time-intensive. Optimal angulation varies by application: splints (0°), crowns (150°-210°), dentures (45°-90°). A 50 μm layer height is preferred for most restorations, with dentures tolerating 100 μm. Commonly used resins employ low-viscosity monomers (e.g., ethoxylated bisphenol A dimethacrylate [Bis-EMA]) that limit stiffness and fast photoinitiators (e.g., ethyl (2,4,6-trimethylbenzoyl) phenylphosphinate [TPO]), requiring 385-405 nm curing.ConclusionsFlexible splints excel in fracture toughness and impact strength; firm splints match milled wear performance. Printed crowns, while weaker than milled options, offer toughness; wear rates remain a concern. Printed denture bases vary in strength but can match or exceed conventional options; printed teeth show favorable wear resistance. Postprocessing, polishing, and bonding protocols critically influence outcomes.Clinical significanceEmploying validated printing parameters, selecting the appropriate resin, and following evidence-based protocols allows clinicians to maximize restoration accuracy and mechanical performance while leveraging 3D printing's efficiency and cost benefits.

Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 41700503 · DOI · PMC13062704

Key reviews and meta-analyses

The most cited review-type papers among PubMed’s best-match results for this heading, listed with bibliographic details only. Follow the links for the full text and access terms.

  • Research article Systematic review of the survival rate and the incidence of biological, technical, and aesthetic complications of single crowns on implants reported in longitudinal studies with a mean follow-up of 5 years [5]
    Jung RE, Zembic A, Pjetursson BE, Zwahlen M, Thoma DS · Clin Oral Implants Res · 2012 · cited 637 times (Europe PMC)
  • Research article Post placement and restoration of endodontically treated teeth: a literature review [6]
    Schwartz RS, Robbins JW · J Endod · 2004 · cited 501 times (Europe PMC)
  • Research article Comparison of survival and complication rates of tooth-supported fixed dental prostheses (FDPs) and implant-supported FDPs and single crowns (SCs) [7]
    Pjetursson BE, Brägger U, Lang NP, Zwahlen M · Clin Oral Implants Res · 2007 · cited 471 times (Europe PMC)
  • Research article All-ceramic or metal-ceramic tooth-supported fixed dental prostheses (FDPs)? A systematic review of the survival and complication rates. Part I: Single crowns (SCs) [8]
    Sailer I, Makarov NA, Thoma DS, Zwahlen M, Pjetursson BE · Dent Mater · 2015 · cited 454 times (Europe PMC)
  • Research article Clinical complications in fixed prosthodontics [9]
    Goodacre CJ, Bernal G, Rungcharassaeng K, Kan JY · J Prosthet Dent · 2003 · cited 283 times (Europe PMC)
  • Research article Tooth preparations for complete crowns: an art form based on scientific principles [10]
    Goodacre CJ, Campagni WV, Aquilino SA · J Prosthet Dent · 2001 · cited 245 times (Europe PMC)

References

  1. Deste Gökay G, Oyar P, Gökçimen G, Durkan R. Static and dynamic stress analysis of different crown materials on a titanium base abutment in an implant-supported single crown: a 3D finite element analysis. . 2024. PMID 38730391 · DOI · PMC11088090
  2. Rahate I, Fulzele P, Thosar N. Comparative evaluation of clinical performance, child and parental satisfaction of Bioflx, zirconia and stainless steel crowns in pediatric patients. . 2023. PMID 38911945 · DOI · PMC11190641
  3. Endres J, Strauss FJ, Siegenthaler M, Naenni N, Jung RE, Thoma DS. Convex Versus Concave Emergence Profile of Implant-Supported Crowns in the Aesthetic Zone: 3-Year Results of a Randomized Controlled Trial. . 2025. PMID 40836504 · DOI · PMC12531365
  4. Sabanik P, Liu TC, Tabatabaeian M, Rocha MG, Surathu N, Lawson NC. A Review of Current Systems, Materials, and Protocols for 3D-Printed Splints, Crowns, and Dentures. . 2026. PMID 41700503 · DOI · PMC13062704
  5. Jung RE, Zembic A, Pjetursson BE, Zwahlen M, Thoma DS. Systematic review of the survival rate and the incidence of biological, technical, and aesthetic complications of single crowns on implants reported in longitudinal studies with a mean follow-up of 5 years. Clin Oral Implants Res. 2012. PMID 23062124 · DOI
  6. Schwartz RS, Robbins JW. Post placement and restoration of endodontically treated teeth: a literature review. J Endod. 2004. PMID 15107639 · DOI
  7. Pjetursson BE, Brägger U, Lang NP, Zwahlen M. Comparison of survival and complication rates of tooth-supported fixed dental prostheses (FDPs) and implant-supported FDPs and single crowns (SCs). Clin Oral Implants Res. 2007. PMID 17594374 · DOI
  8. Sailer I, Makarov NA, Thoma DS, Zwahlen M, Pjetursson BE. All-ceramic or metal-ceramic tooth-supported fixed dental prostheses (FDPs)? A systematic review of the survival and complication rates. Part I: Single crowns (SCs). Dent Mater. 2015. PMID 25842099 · DOI
  9. Goodacre CJ, Bernal G, Rungcharassaeng K, Kan JY. Clinical complications in fixed prosthodontics. J Prosthet Dent. 2003. PMID 12869972 · DOI
  10. Goodacre CJ, Campagni WV, Aquilino SA. Tooth preparations for complete crowns: an art form based on scientific principles. J Prosthet Dent. 2001. PMID 11319534 · DOI

About this article

Sources
NLM Medical Subject Headings (definition, synonyms); NCBI PubMed (counts, identifiers); Europe PMC (open-access abstracts and citation counts).
Verification
Every reference was resolved against PubMed on 2026-11-04; title, year and DOI matched.
Review state
automated source verified; no human expert review has been recorded yet.
Version
1, last updated 2026-11-04.

See how EvidenceLib is built. Spotted an error? Email support@evidencehelix.com.

Evidence strength

EvidenceHelix's computed view of the study designs behind this topic: how common meta-analyses, randomized trials and reviews are, how recent the literature is, and a plain-language reading. It describes the design mix of the literature. It is not a quality appraisal of any study, and it is not medical advice.

Included with the Researcher plan

Reading every article stays free. This computed view is part of the paid plans.

See plans Sign in

Your notes

Notes and highlights stay in this browser only; they are not sent to EvidenceHelix.

Related research topics

  • DenturesDiagnostics and Medical Technology
  • Dental ProsthesisDiagnostics and Medical Technology
  • InlaysDiagnostics and Medical Technology
  • Dental ImplantsDiagnostics and Medical Technology
  • Dental PulpAnatomy and Physiology
  • Crown-Rump LengthAnatomy and Physiology

All 110 articles in Diagnostics and Medical Technology →

At a glance

22,070
PubMed records on this heading
16%
published since 2020
1,022
review articles
970
randomized trials
10
verified references below

Counts come from PubMed on 2026-11-04; they show how much has been written, not how strong the evidence is.

Related topics See all →

  • DenturesDiagnostics and Medical Technology
  • Dental ProsthesisDiagnostics and Medical Technology
  • InlaysDiagnostics and Medical Technology
  • Dental ImplantsDiagnostics and Medical Technology
  • Dental PulpAnatomy and Physiology

My notes & annotations (0)

Nothing yet. Select text and press Highlight, or write a note in the Notes tab. Stored in this browser only.

Sources

  • NLM MeSH record ↗
  • PubMed search used ↗

EvidenceLib is a research-education resource, not medical advice. It does not diagnose, prescribe or recommend starting, stopping or changing any treatment. Talk to a qualified clinician about your own situation. Methods, sources and licences · Rights and removal requests · Legal · Support