Skip to content
EvidenceHelixEvidenceLib · Scientific Encyclopedia
⌘ K

Scientific library

EvidenceLib encyclopediaAll articles A–Z2,100Open textbooks2Cancer study catalog458How it is made

My workspace this browser

Saved pages0Notes & annotations0

Recently viewed

Explore by field

Cancer and Oncology107Genetics and Genomics95Neuroscience110Cardiovascular Medicine105Immunology90Pharmacology99Molecular Biology100Infectious Diseases102Rare and Inherited Diseases106Clinical Research98Anatomy and Physiology542Drugs and Chemicals546
Plans & pricingCompare EvidenceHelix workspace plans
Library›EvidenceLib›Anatomy and Physiology›Dental Arch
Explore more with EvidenceHelix Workspace

Compare studies, analyze evidence and create research reports with premium tools.

Explore Researcher plans

Research reading room

Dental Arch

Anatomy and Physiology · NLM MeSH · updated 2026-10-31 · version 1

Citations verified against PubMedNot yet clinician-reviewed10 referencesApproximately 4 min read

The curve formed by the row of teeth in their normal position in the JAW.

Table of Contents

1. Definition2. Research landscape3. Reading the evidence4. Open-access studies5. Key reviews6. References7. About this article

Definition and research guide

This page combines a MeSH definition, publication statistics and selected research abstracts. It is a starting point for reading the literature, not a medical textbook or a systematic evidence review.

Content available: 4 complete abstracts (832 words), 10 references. Full article text is not stored or reproduced here; follow the PMID, DOI or PMC links to read the original sources and their access terms.

Definition

The curve formed by the row of teeth in their normal position in the JAW. The inferior dental arch is formed by the mandibular teeth, and the superior dental arch by the maxillary teeth.

Definition: NLM Medical Subject Headings (MeSH) scope note (Public domain (U.S. National Library of Medicine); attribution requested). View the MeSH record.

Also known as: Arch, Dental; Arches, Dental; Dental Arches.

Where it fits in the MeSH classification

Broader topics
Jaw
See also
Stomatognathic System

Related concepts

  • Tooth

Research landscape

PubMed indexes 5,651 records tagged with the MeSH heading “Dental Arch” (counts retrieved 2026-10-31). 693 of them (12.3%) were published from 2020 onward, and the busiest period so far is through 1999 with 2,190 records.

Reviews account for 232 records (4.1%) and meta-analyses for 38. Randomized controlled trials number 180 (3.2%) as a share of all records on the topic.

PubMed records by publication periodthrough 1999: 2,190 records; 2000-2009: 1,183 records; 2010-2019: 1,585 records; 2020 onward: 693 records2,190through 19991,1832000-20091,5852010-20196932020 onward
Records in PubMed indexed with this heading, by publication period. Real counts from NCBI E-utilities; the final period covers only part of the current year. Volume reflects how much has been published, not how strong the evidence is.
Show the data
PeriodRecords
through 19992,190
2000-20091,183
2010-20191,585
2020 onward693
Share of records by publication typeReviews: 4.1 percent; Meta-analyses: 0.7 percent; Randomized controlled trials: 3.2 percentReviews4.1% (232)Meta-analyses0.7% (38)Randomized controlled trials3.2% (180)
Share of all PubMed records on this heading that carry each publication type. Types overlap with other records, so the shares do not sum to 100%.
Publication-type chart data
Publication types among 5,651 PubMed records
TypeRecordsShare
Reviews2324.1%
Meta-analyses380.7%
Randomized controlled trials1803.2%

Method: PubMed query "Dental Arch"[MeSH Terms] with publication-type and date filters, retrieved 2026-10-31.

Reading the evidence in anatomy and physiology

Anatomy describes how body structures are built and physiology describes how they normally work, so most findings here are descriptive or mechanistic rather than evidence about treatment. Much of what is known comes from dissection, imaging, tissue studies and experiments in animals, and measurements in healthy volunteers can differ from those in people with disease or at different ages. Normal ranges vary between individuals and populations. Check whether a result was measured in people or in another species, the age and health of the participants, and the method used.

Evidence from open-access studies

These open-access studies come from PubMed’s best-match results for this heading (papers whose main topic it is), ranked here by citation count, with one recent addition. Each abstract is reproduced in full under its recorded open licence so that you can read the authors’ own words. They illustrate the literature; they are not a systematic summary of it. Citation counts measure attention, not reliability or clinical benefit.

Study comparison — selected abstracts, not a systematic review
Study / authorsYearSource label / designEurope PMC citationsLicence / source
Trueness and precision of intraoral scanners in the maxillary dental arch: an in vivo analysis
Winkler J, Gkantidis N
2020Research article
Design not recorded in structured metadata
78cc by
PMID 31980724 · DOI · PMC6981254
Accuracy of four digital scanners according to scanning strategy in complete-arch impressions
Medina-Sotomayor P, Pascual-Moscardó A, Camps I
2018Research article
Design not recorded in structured metadata
68cc by
PMID 30212498 · DOI · PMC6136706
Relationship between vertical facial patterns and dental arch form in class II malocclusion
Grippaudo C, Oliva B, Greco AL, Sferra S, Deli R
2013Research article
Design not recorded in structured metadata
44cc by
PMID 24326093 · DOI · PMC4384936
Evaluation of Arch Dimensions and Bolton Ratio in Manual and Artificial Intelligence Tooth Segmentation
Al-Mashhadany SM, Al-Groosh D, Al-Ubaydi AS
2026Research article
Design not recorded in structured metadata
1cc by
PMID 42138623 · DOI · PMC13178285

Trueness and precision of intraoral scanners in the maxillary dental arch: an in vivo analysis [1]

Research article Winkler J, Gkantidis N · · 2020 · cited 78 times (Europe PMC)

Abstract reading summary — source excerpts
Opening excerpt
Intraoral three-dimensional imaging has gained great interest in dentistry as a mean to generate risk-free imprints of the oral cavity.
Closing excerpt
Thus, the intraoral scanners' appropriateness for highly demanding, spatially extended clinical applications remains questionable.
Interpretation limits
Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (184 words)

Intraoral three-dimensional imaging has gained great interest in dentistry as a mean to generate risk-free imprints of the oral cavity. Accurate intraoral models facilitate proper diagnosis, growth assessment, outcome evaluation, and 3D printing applications. Here, in an actual clinical setup on 12 subjects, we evaluate the trueness and precision of two widely used intraoral scanners (TRIOS 3, 3Shape and CS 3600, Carestream), using an industrial scanner (Artec Space Spider) as a reference. Surface based matching was implemented using the iterative closest point algorithm (ICP). Trueness of the intraoral scans was analyzed by measuring their distance from the reference scan, in the upper buccal front area. Precision was tested through the distance of repeated scans regarding the whole dental arch, following superimpositions in the buccal front and in the whole dental arch area. TRIOS 3 displayed slightly higher precision (approximately 10 μm) compared to CS 3600, only after superimposition on the whole dental arch (p 0.05). However, in individual cases and in various, not spatially defined areas, higher imprecision was evident. Thus, the intraoral scanners' appropriateness for highly demanding, spatially extended clinical applications remains questionable.

Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 31980724 · DOI · PMC6981254

Accuracy of four digital scanners according to scanning strategy in complete-arch impressions [2]

Research article Medina-Sotomayor P, Pascual-Moscardó A, Camps I · · 2018 · cited 68 times (Europe PMC)

Abstract reading summary — source excerpts
Opening excerpt
Statement of problemAlthough there are specific and general digital scanning guidelines depending on the system used, it is important to have the necessary flexibility in the acquisition of three-dimensional (3D) images to adapt to any clinical situation without affecting accuracy.
Closing excerpt
ConclusionsThe digital impression systems used in the experiment provided sufficient flexibility for the acquisition of 3D images without this affecting the accuracy of the scanner.
Interpretation limits
Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (222 words)

Statement of problemAlthough there are specific and general digital scanning guidelines depending on the system used, it is important to have the necessary flexibility in the acquisition of three-dimensional (3D) images to adapt to any clinical situation without affecting accuracy.PurposeThe purpose of this in vitro study was to identify and compare the scanning strategy with the greatest accuracy, in terms of trueness and precision, of four intraoral scanners in the impression of a complete dental arch.Material and methodsFour digital scanners were evaluated with a 3D measuring software, using a highly accurate reference model obtained from an industrial scanner as a comparator. Four scanning strategies were applied 10 times on a complete maxillary arch cast inside a black methacrylate box. The data were statistically analyzed using one-way analysis of variance (ANOVA) and post hoc comparisons with Tamhane T2 test.ResultsThe trueness of the Trios and iTero system showed better results with strategy "D," Omnicam with strategy "B," and True Definition with strategy "C". In terms of precision, both iTero and True Definition showed better results with strategy "D", while Trios showed best results with strategy "A" and Omnicam with strategy "B". There were significant differences between the scanning strategies (p0.05).ConclusionsThe digital impression systems used in the experiment provided sufficient flexibility for the acquisition of 3D images without this affecting the accuracy of the scanner.

Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 30212498 · DOI · PMC6136706

Relationship between vertical facial patterns and dental arch form in class II malocclusion [3]

Research article Grippaudo C, Oliva B, Greco AL, Sferra S, Deli R · · 2013 · cited 44 times (Europe PMC)

Abstract reading summary — source excerpts
Opening excerpt
BackgroundThe purpose of this study is to evaluate the relationship between dental arch form and the vertical facial pattern determined by the angle between the mandibular plane and the anterior cranial base (Sella-nasion/mandibular plane angle (SN-MP)) in skeletal class II untreated patients.
Closing excerpt
On the contrary, the lower arch form was not related to the mandibular divergence.
Interpretation limits
Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (168 words)

BackgroundThe purpose of this study is to evaluate the relationship between dental arch form and the vertical facial pattern determined by the angle between the mandibular plane and the anterior cranial base (Sella-nasion/mandibular plane angle (SN-MP)) in skeletal class II untreated patients.MethodsA sample of 73 Caucasians patients with untreated skeletal class II in permanent dentition was divided into three groups according to the values of the angle SN-MP. An evaluation of the arch form was performed by angular and linear relation values on each patient. Regression analysis was used to determine the statistical significance of the relationships between SN-MP angle and dental arch form. The differences among the three groups were analyzed for significance using a variance analysis.ResultsA decrease of the upper arch transversal diameters in high SN-MP angle patients and an increase in low angle SN-MP ones (PConclusionsThe results showed the association between the upper dental arch form and the vertical facial pattern. On the contrary, the lower arch form was not related to the mandibular divergence.

Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 24326093 · DOI · PMC4384936

Evaluation of Arch Dimensions and Bolton Ratio in Manual and Artificial Intelligence Tooth Segmentation [4]

Research article Al-Mashhadany SM, Al-Groosh D, Al-Ubaydi AS · · 2026 · cited 1 times (Europe PMC)

Abstract reading summary — source excerpts
Opening excerpt
ObjectiveA 3D tooth model segmented with the use of deep learning (DL) method program (CephX) as well as MIMICS software (manual segmentation) will be evaluated for reliability in the presented work.
Closing excerpt
However, caution is advised when interpreting certain Bolton ratio values because discrepancies and lower agreement may occur.
Interpretation limits
Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (258 words)

ObjectiveA 3D tooth model segmented with the use of deep learning (DL) method program (CephX) as well as MIMICS software (manual segmentation) will be evaluated for reliability in the presented work. In addition, the segmented model was compared with the intraoral scan (IOS)-generated 3D tooth model in terms of the Bolton ratio and arch dimensions.Methods and materialsA total of 30 patients attending the College of Dentistry/University of Baghdad with records of IOSs and CBCT scans were included. CBCT has been transformed into a 3D digital tooth model segmented with the use of MIMICS software and an AI-based program (CephX), and the Bolton ratio and arch dimensions (length and width) were measured utilizing Geomagic Control X software. Statistical analyses, including the mean and standard deviation, were performed, and a paired t-test was used to assess the systematic bias between the three methods. Bland-Altman plots and intraclass correlation (ICC) analysis were used to assess the agreement between the three methods.ResultsThe means of CephX, MIMICS, and IOS of all analyses were mostly similar, and the difference between them was greatest in the anterior Bolton ratio of IOS and CephX images. The systematic bias demonstrated no significant difference (p value > 0.05) between CephX and MIMICS, but CephX versus IOS and MIMICS versus IOS demonstrated significant differences (p value ConclusionsDigital and AI-driven tooth segmentation (MIMICS and CephX), and IOS methods generally provide consistent and reliable measurements in terms of the Bolton ratio and arch dimensions. However, caution is advised when interpreting certain Bolton ratio values because discrepancies and lower agreement may occur.

Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 42138623 · DOI · PMC13178285

Key reviews and meta-analyses

The most cited review-type papers among PubMed’s best-match results for this heading, listed with bibliographic details only. Follow the links for the full text and access terms.

  • Research article Accuracy of Intraoral Scanners: A Systematic Review of Influencing Factors [5]
    Abduo J, Elseyoufi M · Eur J Prosthodont Restor Dent · 2018 · cited 216 times (Europe PMC)
  • Research article Stability and relapse of dental arch alignment [6]
    Little RM · Br J Orthod · 1990 · cited 142 times (Europe PMC)
  • Research article Accuracy, reliability, and efficiency of intraoral scanners for full-arch impressions: a systematic review of the clinical evidence [7]
    Goracci C, Franchi L, Vichi A, Ferrari M · Eur J Orthod · 2016 · cited 134 times (Europe PMC)
  • Research article Validity and reliability of intraoral scanners compared to conventional gypsum models measurements: a systematic review [8]
    Aragón ML, Pontes LF, Bichara LM, Flores-Mir C, Normando D · Eur J Orthod · 2016 · cited 131 times (Europe PMC)
  • Research article A review of the shortened dental arch concept focusing on the work by the Käyser/Nijmegen group [9]
    Kanno T, Carlsson GE · J Oral Rehabil · 2006 · cited 123 times (Europe PMC)
  • Research article Long-term dental arch changes after rapid maxillary expansion treatment: a systematic review [10]
    Lagravere MO, Major PW, Flores-Mir C · Angle Orthod · 2005 · cited 86 times (Europe PMC)

References

  1. Winkler J, Gkantidis N. Trueness and precision of intraoral scanners in the maxillary dental arch: an in vivo analysis. . 2020. PMID 31980724 · DOI · PMC6981254
  2. Medina-Sotomayor P, Pascual-Moscardó A, Camps I. Accuracy of four digital scanners according to scanning strategy in complete-arch impressions. . 2018. PMID 30212498 · DOI · PMC6136706
  3. Grippaudo C, Oliva B, Greco AL, Sferra S, Deli R. Relationship between vertical facial patterns and dental arch form in class II malocclusion. . 2013. PMID 24326093 · DOI · PMC4384936
  4. Al-Mashhadany SM, Al-Groosh D, Al-Ubaydi AS. Evaluation of Arch Dimensions and Bolton Ratio in Manual and Artificial Intelligence Tooth Segmentation. . 2026. PMID 42138623 · DOI · PMC13178285
  5. Abduo J, Elseyoufi M. Accuracy of Intraoral Scanners: A Systematic Review of Influencing Factors. Eur J Prosthodont Restor Dent. 2018. PMID 29989757 · DOI
  6. Little RM. Stability and relapse of dental arch alignment. Br J Orthod. 1990. PMID 2207055 · DOI
  7. Goracci C, Franchi L, Vichi A, Ferrari M. Accuracy, reliability, and efficiency of intraoral scanners for full-arch impressions: a systematic review of the clinical evidence. Eur J Orthod. 2016. PMID 26487391 · DOI
  8. Aragón ML, Pontes LF, Bichara LM, Flores-Mir C, Normando D. Validity and reliability of intraoral scanners compared to conventional gypsum models measurements: a systematic review. Eur J Orthod. 2016. PMID 27266879 · DOI
  9. Kanno T, Carlsson GE. A review of the shortened dental arch concept focusing on the work by the Käyser/Nijmegen group. J Oral Rehabil. 2006. PMID 17002745 · DOI
  10. Lagravere MO, Major PW, Flores-Mir C. Long-term dental arch changes after rapid maxillary expansion treatment: a systematic review. Angle Orthod. 2005. PMID 15825776 · DOI

About this article

Sources
NLM Medical Subject Headings (definition, synonyms); NCBI PubMed (counts, identifiers); Europe PMC (open-access abstracts and citation counts).
Verification
Every reference was resolved against PubMed on 2026-10-31; title, year and DOI matched.
Review state
automated source verified; no human expert review has been recorded yet.
Version
1, last updated 2026-10-31.

See how EvidenceLib is built. Spotted an error? Email support@evidencehelix.com.

Evidence strength

EvidenceHelix's computed view of the study designs behind this topic: how common meta-analyses, randomized trials and reviews are, how recent the literature is, and a plain-language reading. It describes the design mix of the literature. It is not a quality appraisal of any study, and it is not medical advice.

Included with the Researcher plan

Reading every article stays free. This computed view is part of the paid plans.

See plans Sign in

Your notes

Notes and highlights stay in this browser only; they are not sent to EvidenceHelix.

Related research topics

  • Rib CageAnatomy and Physiology
  • AcetabulumAnatomy and Physiology
  • AcromionAnatomy and Physiology
  • CalcaneusAnatomy and Physiology
  • Cervical VertebraeAnatomy and Physiology
  • ChinAnatomy and Physiology

All 542 articles in Anatomy and Physiology →

At a glance

5,651
PubMed records on this heading
12%
published since 2020
232
review articles
180
randomized trials
10
verified references below

Counts come from PubMed on 2026-10-31; they show how much has been written, not how strong the evidence is.

Related topics See all →

  • Rib CageAnatomy and Physiology
  • AcetabulumAnatomy and Physiology
  • AcromionAnatomy and Physiology
  • CalcaneusAnatomy and Physiology
  • Cervical VertebraeAnatomy and Physiology

My notes & annotations (0)

Nothing yet. Select text and press Highlight, or write a note in the Notes tab. Stored in this browser only.

Sources

  • NLM MeSH record ↗
  • PubMed search used ↗

EvidenceLib is a research-education resource, not medical advice. It does not diagnose, prescribe or recommend starting, stopping or changing any treatment. Talk to a qualified clinician about your own situation. Methods, sources and licences · Legal · Support