Cancer and Oncology182Genetics and Genomics170Neuroscience185Cardiovascular Medicine180Immunology162Pharmacology174Molecular Biology161Infectious Diseases150Rare and Inherited Diseases181Clinical Research173Anatomy and Physiology617Drugs and Chemicals621Psychiatry and Psychology75Public Health and Nutrition64Diagnostics and Medical Technology15
Plans & pricingCompare EvidenceHelix workspace plans
Library›Open-access articles›Article

Continue where you left off ()

Explore more with EvidenceHelix Workspace

Compare studies, analyze evidence and create research reports with premium tools.

Explore Researcher plans

EvidenceLib · Open-access article · Anatomy and Physiology

Wearable devices for continuous monitoring of biosignals: Challenges and opportunities

Tucker Stuart, Jessica Hanna, Philipp Gutruf

APL Bioengineering 2022 · doi:10.1063/5.0086935

CC BY 4.0Full textApproximately 33 min read168 references

Table of Contents

AbstractCRITERIA FOR LONG-TERM WEARABLE DEVICESWIRELESS POWER TRANSFER TECHNIQUES FOR BATTERY-FREE WEARABLE DEVICESCONTINUOUS SENSING SYSTEMSCURRENT LIMITATIONS OF WEARABLE DEVICESOPPORTUNITIES FOR LONG-TERM WEARABLE DEVICESOPPORTUNITIES FOR ARTIFICIAL INTELLIGENCE AS MEANS OF ON-SENSOR AUTOMATED DATA PROCESSINGDISCUSSIONReferences

Abstract

The ability for wearable devices to collect high-fidelity biosignals continuously over weeks and months at a time has become an increasingly sought-after characteristic to provide advanced diagnostic and therapeutic capabilities. Wearable devices for this purpose face a multitude of challenges such as formfactors with long-term user acceptance and power supplies that enable continuous operation without requiring extensive user interaction. This review summarizes design considerations associated with these attributes and summarizes recent advances toward continuous operation with high-fidelity biosignal recording abilities. The review also provides insight into systematic barriers for these device archetypes and outlines most promising technological approaches to expand capabilities. We conclude with a summary of current developments of hardware and approaches for embedded artificial intelligence in this wearable device class, which is pivotal for next generation autonomous diagnostic, therapeutic, and assistive health tools.

CRITERIA FOR LONG-TERM WEARABLE DEVICES

Wearable devices have seen an acute increase in popularity over the last 10 years.1–7 As the rate of proliferation of wearable systems and technological advances increases, understanding end user behaviors and factors that influence a user's decision to utilize wearable devices is an important factor to consider in the development of new device archetypes, specifically when the technologies are used as diagnostic tools. To understand the multifaceted decision process, several models have been developed to understand technology acceptance and long-term compliance. The two most popular models are the technology acceptance model8 and the unified theory of acceptance and use of the technology model9 with other works focused on expanding and refining these models.10–23 Key outcomes from these models are detailed in Fig. 1(a), which shows the primary factors of wearable technology systems that influence device acceptance and adoption. Among these factors, there are three primary categories, which include the following: intrinsic device hardware properties such as comfort, safety, and data relevancy and user-centered subjective factors such as perceived ease of use, perceived value, and social acceptance. When engaging in fundamental research and device design, these factors play a large role in the acceptance and adoption of new devices and, thus, must be considered early in the design process to enable impact.

FIG. 1. Introduction into current wearable systems: (a) illustration showing key aspects for chronic user compliance with wearable medical devices. (b) Graph showing metrics of user retention for fitness wearables.25 Reproduced with permission from Chandrasekaran et al., J. Med. Internet Res. 22, e22443 (2020). Copyright 2020 Authors, licensed under a Creative commons Attribution (CC BY) license. (c) Graph showing user compliance with wearable monitors over a 2-year period ledger.27 Reproduced with permission from D. Ledger and McCaffrey, Endeavour Partners 200, 1 (2014). Copyright 2014 Authors, licensed under a Creative commons Attribution (CC BY) license. (d) Illustrations outlining wireless power transfer techniques' battery-free or chronic wearable devices. (e) Summary of power harvesting techniques used for autonomous wearable devices. (Figure not reproduced here; see the original article.)

The US market for wearable devices reached $24.57 billion in 2018 with a projected growth rate of 24.7% annually to $139.35 billion by 202624 with nearly 30% of the population reporting using a wearable device, of which 47% using devices every day.25 A graph showing survey data from a sample population of 4551 participants is shown in Fig. 1(b). From this study, it was found that younger age demographics contribute more to the ownership and adoption of wearable sensing systems, whereas older users are less likely to adopt these devices (odds ratio 0.46–0.57). Additionally, it was shown that respondents who reported a high level of technological affinity were more likely to adopt wearable devices than those who were less familiar (odds ratio 1.33).25 These statistics demonstrate that, in general, younger and health-conscious users who are interested in fitness optimization and older populations who are focused on overall health improvement are driving market expansion, particularly accentuated during the COVID-19 pandemic.26

Despite widespread adoption among several subpopulations, conventional wearable devices do not meet many standards set out by acceptance models, as many devices fail to drive long-term user engagement. Figure 1(c) summarizes user engagement with wearable systems over a 2 year period.27 In this study, it was reported that a third of users who owned a modern activity tracking device stopped using it within 6 months of receiving it. While temporal decreases in user compliance are widely studied and depend on the formfactor of the device, users may choose to discontinue interaction with a wearable system because of perceived complication of use, a failure to integrate with existing infrastructure, discomfort, and lack of perceived value of the insight collected from wearing the device.28–30 These aspects of human behavior are key for long-term compliance with wearable systems, where software approaches to promote habit formation, social motivation, and goal reinforcement are important to maintain perceived value and usefulness.31 A barrier in practical applications is a safe and reliable biological interface. Biocompatibility and soft mechanics can reduce the risk of irritation at interfaces whereas suitable encapsulation can eliminate the risk of harmful interaction with the skin.32

In addition to these factors, there are additional engineering design challenges, including communication security and privacy, power consumption, and transmission reliability (including loss of real time information),7,33 that must be overcome to enable truly long-term, sustainable wearable devices that provide less burden to the wearer and result in higher compliance with longer wear time, all critical aspects to enable powerful health diagnostic devices.7,32,33

Wearable systems for noninvasive monitoring of physiological processes and biomarkers for disease detection, coupled with advances in electronic systems, materials science,34,35 and sensor technology5,32 seek to overcome these challenges. The device class is defined by wireless and battery-free operation, soft mechanics, and high-fidelity sensing capabilities to increase both user compliance and expand sensing functionality of wearable systems.36 Key aspects of this device class are strategies for wireless power transfer and energy harvesting, which are considered a bottleneck that drives device composition while power availability prescribes functional limitations. Commercially available devices generally utilize a form of rechargeable lithium-ion or lithium-polymer battery. Batteries impose device sizing constraints due to their large formfactor (>1 × 1 cm2) but are available with a wide range of capacities that can handle continuous device operation of 8–10 h. In an effort to render battery powered systems more mechanically compliant, development of stretchable cells that are able to deform and integrate seamlessly into textiles37–39 has proliferated; however, mechanical compliance comes at the expense of energy density resulting in larger device footprints. Wireless powering modalities for wearable systems can be categorized into two subgroups, namely, power transfer approaches that capture energy cast by external infrastructure and energy harvesting approaches that utilize existing forms of energy to power the sensor systems.40 Figure 1(d) details external power transfer techniques that are commonly implemented in chronic wearable device systems.

WIRELESS POWER TRANSFER TECHNIQUES FOR BATTERY-FREE WEARABLE DEVICES

Radio frequency (RF) power transfer, which is a popular modality for wearable systems with functional operation distances of 60 cm and low tissue absorption (<20 mW/kg), makes it appealing for wearable applications directly on the skin.41–43 The most popular of these RF transfer modalities is near-field magnetic resonance coupling (MRC)40 that relies on a primary transmission coil and a resonantly coupled secondary coil that is able to provide up to 500 mW.42 Because of relatively robust electromagnetic makeup, technology can be united with mechanical concepts such as rigid island and stretchable interconnects to enable skin-like mechanical feel with robust operation even under large deformations,44 making it a popular approach for epidermal electronics. Most recent methods increase the functional distance through strategies such as near-field enabled textiles;45,46 MRC is generally confined to less than 1 m (Ref. 42) with high-powered transmitters and elaborate antenna schemes or sub-10 cm range with smart phones and, therefore, requires applications that either rely on sporadic readings or operation in close proximity to transmission hardware. While infrastructure is ubiquitous through near field communication (NFC) enabled phones, this solution is difficult to implement for continuous chronic operation due to the proximity requirement to the transmitter, which requires a high level of user interaction with the devices. Another method of RF power transfer focuses on the far-field regime to extend the operational distances of devices beyond 1 m and generally uses higher frequencies to sufficiently miniaturize the receiver antenna systems resulting in a harvested power of 1–100 mW depending on the distance, orientation, dielectric environment, power, and antenna gain of the transmitter and receiver.47–49 This allows for continuous communication strategies but requires on-body antenna structures and proximity (0.5–3 m) to power transfer hardware.47 Tissue adsorption (0.1–6 W/kg) and legislative limits of far field power transmission are considered the bottle neck for this technology. Strategies to improve antenna performance on the skin include implementation of 3D structures to reduce loss associated with the skin while maintaining mechanical performance.40 The power transfer scheme is suitable for chronic applications, and examples with operational times over weeks are demonstrated.47

Another power transfer technique uses photovoltaic cells (PVCs) for converting optical energy into electrical power.50 The PVCs in combination with near infrared and visible light sources can also be used as a power transfer scheme and are able to generate power densities of up to an estimated 1.05 mW cm−2 with dedicated light sources and 14.6 μW cm−2 from ambient light sources.51–53 Systems can be embedded into textiles50,54–57 to provide power for wearable sensor devices able to detect cardiac signals.53 Fabrication of inorganic PVCs using processes with the ability to create ultra-small rigid island and flexible interconnect schemes to provide harvesting capabilities without compromising device mechanics. Demonstrations with this technology have shown harvesting capabilities for low-powered electronic systems; however, the current energy density of PVCs renders their wearable application limited.53

Energy harvesting used in wearable systems has become increasingly popular, as they do not require external power transfer infrastructure for operation. A technological overview of these power harvesting modalities is summarized in Fig. 1(e). Piezoelectric and triboelectric generators convert various mechanical energies into electrical power58 with power densities of 0.01–1.32 mW cm−2 (Refs. 59–61) and conversion efficiencies of 50%–85% (Refs. 62–64) suitable for low power wearable applications (<5 mW). While current efficiencies and power densities require large surface areas for adequate power harvesting, integration of these generators into textile components61 enables low sampling rate continuous applications. One downside of these modalities is the requirement for human motion for power, which renders the system ineffective during periods of sleep or rest.

Biofuel cells aimed at powering wearable devices using sweat as electrochemical power source are suitable for short term usage in epidermal electronic applications.65–67 Devices demonstrate a power density of 1–3.5 mW cm−2, sufficient to power sensing modalities and BLE SoC modules for data aggregation and communication for up to 5 h. These biofuel cells can maintain a low mechanical profile, enabling integration of soft, flexible sensor systems; however, they may suffer inconsistent performance due to difference in physiology from user to user based on differences in sweat rates and ion concentrations and have a fundamental time limit of operation associated with materials used.

Thermoelectric generators that convert difference of body temperature and ambient temperature into electrical energy to power wearable devices68–71 are based on the Seebeck effect72 that has the advantage of omission of rectification circuits; however, they only offer modest power densities and can only power applications with ultra-low power requirements (<1 mW). Devices with average power densities between 5 and 15 μW cm−2 (Refs. 73 and 74) have been demonstrated requiring either large device size or ultra-low power operation limiting utility of this modality to measure very slow biosignals and require specialized data transmission schemes. The advantage of this harvesting method is that most of the time there is a temperature gradient that can power devices continuously.

CONTINUOUS SENSING SYSTEMS

Biophysical sensors

Epidermal sensors, specifically thin, battery-free solutions increase signal fidelity because of the reduction of interfacial challenges such as motion artefacts36,75,76 and offer access to biomarkers in biofluids (sweat and interstitial fluid), and many physiological indicators that if monitored in real time with high-fidelity expand capabilities in diagnostics and therapeutics.40,77 Because of the small form factor and mechanical compliance with the skin, this device class has the prospect of increasing user compliance by reducing device interaction and discomfort and increasing signal fidelity through intimate sensor interfaces resulting in a higher value of the captured biosignals78,79 and increasing the likelihood of long-term adoption.

Lin et al.80 demonstrated a multimodal system based on skin-mounted wireless sensors powered by near-field-enabled clothing. Figure 2(a) shows the system in which the wireless sensors are attached directly onto the skin to continuously collect physiological and gait parameters. Lightweight and flexible negative temperature coefficient (NTC)-thermistor based temperature sensors and strain gauge sensors are combined with a commercial NFC chipset. These sensors are wirelessly connected to near-field-enabled clothing, which are compatible with NFC-enabled devices (such as smart phones) serving as the power supply and readout device for the distributed sensors on the body [Fig. 2(b)]. To improve the conventional NFC range of operation (<4 cm for mobile devices), near field relays were designed, which allow operation up to a meter distance. Relying on multiple inductor patterns, the authors demonstrated the ability to power up to six sensor nodes. Power transfer efficiency to each of the six sensor nodes is measured to be about 3%, which is suitable to maintain stable communication. In one experiment, a temperature sensor placed under the armpit and a strain sensor placed on the knee are used to continuously monitor axillary temperature and running gait, respectively, during exercise [Fig. 2(c)]. Because sensor nodes are readout with a device that is always carried with the user (smartphone), the likelihood of discontinuation of use because of frequent recharging of multiple gadgets is eliminated and the possibility to place devices and physiologically relevant locations increases data relevancy and fidelity offering the opportunity to increase the perceived value.

FIG. 2. Wireless battery-free biophysical sensors. (a) Schematic illustration of wireless, battery-free multimodal wireless skin-mounted sensors powered by near-field-enabled clothing.80 Reproduced with permission from Lin et al., Nat. Commun. 11, 1–10 (2020). Copyright 2020 Authors, licensed under a Creative Commons Attribution (CC BY) license. (b) Illustration of conductive thread to relay power and data transfer for operation of the skin mounted sensors.80 Reproduced with permission from Lin et al., Nat. Commun. 11, 1–10 (2020). Copyright 2020 Authors, licensed under a Creative Commons Attribution (CC BY) license. (c) Graph showing continuous monitoring of axillary temperature and running gait during exercise using epidermal sensors, compared with the gold standard wired system.80 Reproduced with permission from Lin et al., Nat. Commun. 11, 1–10 (2020). Copyright 2020 Authors, licensed under a Creative Commons Attribution (CC BY) license. (d) Photographic image of the electrocardiogram (ECG) device capable of measuring HR, SpO2, and RR along with central-skin and peripheral-skin temperature to monitor neonatal intensive care (NICU). Reproduced with permission from Chung et al., Nat. Med. 26, 418–429 (2020). Copyright 2020 Springer Nature. (e) Photographic image showing the preterm infant in NICU bed equipped with the NFC antenna system to power the battery-free ECG and photophlethysmographgy (PPG) sensors placed on the chest and the foot of a newborn, respectively.82 Reproduced with permission from Chung et al., Science 363, eaau0780 (2019). Copyright 2019 Authors, licensed under a Creative Commons Attribution (CC BY) license. (f) Graph showing in vivo data collection including HR, SpO2, Temp, and acceleration. Reproduced with permission from Chung et al., Nat. Med. 26, 418–429 (2020). Copyright Springer Nature. (g) Photographic image of an epidermal wireless thermal sensor (eWTS) for thermal conductivity measurements.83 Reproduced with permission from Krishnan et al., Small 14, 1–13 (2018). Copyright 2018 Wiley‐VCH Verlag GmbH & Co. KGaA, Weinheim. (h) Optical image showing readout from the eWTS placed on the forearm using a smartphone.83 Reproduced with permission from Krishnan et al., Small 14, 1–13 (2018). Copyright 2018 Wiley‐VCH Verlag GmbH & Co. KGaA, Weinheim. (i) Graph of thermal conductivity measured continuously using the eWTS for 1 week and compared to the gold standard electromagnetic method evaluating skin hydration.83 Reproduced with permission from Krishnan et al., Small 14, 1–13 (2018). Copyright 2018 Wiley‐VCH Verlag GmbH & Co. KGaA, Weinheim. (Figure not reproduced here; see the original article.)

Multimodal wireless and battery-free devices for vital sign analysis based on epidermal sensors are described in Refs. 81 and 82. They are capable of measuring heart rate (HR), oxygen saturation (SpO2), and respiratory rate (RR) along with central-skin and peripheral-skin temperature to monitor patients in the neonatal intensive care (NICU) and pediatric intensive care unit [Fig. 2(d)]. The devices also include inertial measurement units (IMUs) to track motion and body orientation and voice biomarkers related to intonation and temporal aspects of crying, serving as a good proxy for systolic blood pressure. Battery-free operation is achieved with MRC [Fig. 2(e)]. The NICU bed is equipped with a 13.56 MHz antenna system to power the device without any direct physical contact to the newborns. A Bluetooth low energy (BLE) system-on-a-chip (SoC) enables robust wireless data transmission and real-time display of the collected data within an operational range of 10 m. Soft mechanics are engineered through an elastomeric enclosure with an inner silicone-gel liner decoupling strain from electronics and provide a soft interface to sensitive skins and highly curved anatomical features of newborns. The system was tested during and after a typical kangaroo care study, which features frequent skin-to-skin contact with parents. Figure 2(f) presents the HR, SpO2, skin-temperature, and the accelerometry data. The system demonstrates reliable and accurate measurements, comparable with the gold standard, hard-wired techniques, for continuous monitoring periods of up to 24 h. Motion artifacts that occur during clinical treatment, feeding, and medical imaging are reduced in scale and prevalence because of the wireless operation, mechanical stability, and wearability of the device increasing recording fidelity. The core benefit of this embodiment is the extended wearability and chronic operation without the need of device interaction that can have substantial effects on preterm infants due to very fragile skin where instruments can leave lifelong scars and the ability to improve clinical outcomes with additional skin to skin interaction with parents, which are otherwise interrupted or reduced by wired connections.84

Figure 2(g) presents a demonstration of epidermal electronic devices that feature a wireless thermal actuator and sensor (eWTS) with MRC and NFC for power and data transmission for thermal conductivity measurements.83 When placed on the skin surface, low-power thermal actuation (2 mW) is applied through a low thermal mass thin film heater in epidermal contact with the skin resulting in confined heating. Temperature measurements with the actuator that also functions as a sensing element produces time-dependent data [ΔT(t)], which is evaluated to calculate the thermal conductivity (k) and thermal diffusivity. Such measurements can provide valuable information on blood flow, skin hydration, and wound healing.83 Figure 2(h) shows readout from the eWTS placed on the forearm with a smartphone using NFC. The battery-free, lightweight design of these sensors enable continuous monitoring of skin temperature, skin hydration, and thermal conductivity for up to one week without interfering with daily routines such as exercising, bathing, and sleeping [Fig. 2(i)]. These characteristics serve as a demonstration for the implementation of systems that can record chronically for an extended period of time, providing valuable information about the progression of diseases and the effectiveness of the treatments. An example is the diagnosis of cerebral shunt function failure, which requires continous monitoring to provide lifesaving feedback on the implant state with location (neck) not accessible to current wearable tech.85

Biochemical sensors

In addition to expanding sensing capabilities and broadening the use case as well as user compliance of biophysical sensor systems, epidermal form factors of wireless and battery-free devices enable noninvasive investigation into biochemical makers, such as lactate,86–89 pH,65,86,90,91 and glucose,86,87,89,92,93 without the need for transdermal device penetration, substantially reducing the barrier of device usage, expanding analysis, screening, and testing schemes.

Figure 3(a) shows an illustration of such a device, enabling continuous sweat analysis61 and utilizing human motion through a free standing triboelectric nanogenerator (FTENG) [shown in Fig. 3(b)], which can convert the mechanical energy of human motion into electrical energy to power sensing and communication electronics.58,95–97 The sensing component of the device features a biosensor array with on-body, laser-patterned microfluidics channel for sweat-based pH and sodium concentration detection. This biosensor array features a dynamic range of pH (4–8) and sodium concentrations (12.5–200 mM). System performance for this study was evaluated during 30-minute durations of the exercise against a battery-powered system with high compliance between the two devices. [Data are presented in Fig. 3(c).] For applications with slow physiological processes such as changes in sweat composition, a high sampling rate is not necessary, making the FTENG powered system a viable alternative to electrochemical power supplies and providing adequate power supply for device function during exercise.

FIG. 3. Wearable biochemical sensing devices: (a) graphical illustration showing device function and motion harvested by triboelectric nanogenerator (TENG) to power electrolyte sweat analysis.61 Reproduced with permission from Yu et al., Sci. Adv. 6, eaay9842 (2021). Copyright 2021 Authors, licensed under a Creative Commons Attribution (CC BY) license. (b) Image showing device applied to the subject's torso.61 Reproduced with permission from Yu et al., Sci. Adv. 6, eaay9842 (2021). Copyright 2021 Authors, licensed under a Creative Commons Attribution (CC BY) license. (c) Real time pH and sodium concentrations measured with the FWS3 device compared to the system charged with the lithium battery.61 Reproduced with permission from Yu et al., Sci. Adv. 6, eaay9842 (2021). Copyright 2021 Authors, licensed under a Creative Commons Attribution (CC BY) license. (d) Image of multimodal performance biomarker sweat analysis device interfacing with a smartphone for analysis readout.86 Reproduced with permission from Bandodkar et al., Sci. Adv. 5, eaav3294 (2019). Copyright 2019 Authors, licensed under a Creative Commons Attribution (CC BY) license. (e) Images showing device operation during perspiration.86 Reproduced with permission from Bandodkar et al., Sci. Adv. 5, eaav3294 (2019). Copyright 2019 Authors, licensed under a Creative Commons Attribution (CC BY) license. (f) Data correlation between seat-based glucose and lactate readings and measured values from blood level measurements.86 Reproduced with permission from Bandodkar et al., Sci. Adv. 5, eaav3294 (2019). Copyright 2019 Authors, licensed under a Creative Commons Attribution (CC BY) license. (g) Schematic illustration showing the electrical device operation principle of contact lens based electrochemical sensing of tear fluid.94 Reproduced with permission from Ku et al., Sci. Adv. 6, eabb2891 (2020). Copyright 2020 Authors, licensed under a Creative Commons Attribution (CC BY) license. (h) Illustration displaying device and sensor composition integrated in contact.94 Reproduced with permission from Ku et al., Sci. Adv. 6, eabb2891 (2020). Copyright 2020 Authors, licensed under a Creative Commons Attribution (CC BY) license. (I) In vivo cortisol concentrations collected simultaneously from both eyes of a subject.94 Reproduced with permission from Ku et al., Sci. Adv. 6, eabb2891 (2020). Copyright 2020 Authors, licensed under a Creative Commons Attribution (CC BY) license. (j) Illustration of biofuel-powered energy harvesting from perspiration to power electrochemical analysis of sweat. Reproduced with permission from Yu et al., Sci. Robot. 5, 1–14 (2020). Copyright 2020 AAAS. (k) Image of the device located on the subject's arm. Reproduced with permission from Yu et al., Sci. Robot. 5, 1–14 (2020). Copyright 2020 AAAS. (l) Real-time data collection of urea and NH4+ concentrations from a forehead mounted device. Reproduced with permission from Yu et al., Sci. Robot. 5, 1–14 (2020). Copyright 2020 AAAS. (Figure not reproduced here; see the original article.)

Among other metabolites of interest, metabolic byproducts, such as glucose and lactate, are important biomarkers in many disease paradigms and human performance analysis and are essential in understanding underlying metabolic processes. While many of these biomarkers are present in biofluids such as blood, they traditionally require transdermal probing for accurate recording, increasing the barrier of usage significantly and making noninvasive alternatives compelling to develop. One device that provides exemplary monitoring capabilities with multimodal sensing capabilities is featured in Fig. 3(d).86 The device presented in this work utilizes adhesive application to the epidermis to collect sweat via epifluidics, a soft microfluidic wearable designed to capture sweat and route it to analysis chambers that house colorimetric, volumetric, and electrochemical analytes. The device utilizes a multimodal approach for its sensing functionality: a disposable patch for collection and colorimetric analysis of sweat, and a reusable electronics module for electrochemical detection of sweat-based glucose and lactate. The device, shown in Fig. 3(e), utilizes magnets to attach the components together. NFC is used to enable digital and continuous readout of the biofuel cell-based glucose and lactate sensors. This allows the user to utilize a smartphone device for readout while launching an app to trigger photographic colorimetric readout of ion concentrations and sweat rate. Figure 3(f) shows a comparison between the sensor output of sweat-based lactate and glucose concentrations to blood measurements over a 2-day period. In this study, measurements were taken during periods of fasting, right after a meal, and in the evening. In the plots, spikes in glucose concentrations after meals are observed in both the blood and sweat measurements, while trends in lactate concentrations were consistent throughout the trial. The reusable, low-cost nature of these devices provides a favorable alternative to currently invasive monitoring.

Integration of battery-free electronics into contact lenses offers direct access to tear fluid, which is rich in biomarkers that can be harnessed for diagnostic purposes.92,94,98,99 Device can also be made chronically wearable because there is little cell turnover. One such device is outlined in Fig. 3(g) and operates using NFC powering and communication for the readout of tear-based cortisol concentrations.94 Cortisol is a biomarker for endocrine disorders such as Cushing syndrome, as well as an early precursor for neurological disorders such as stress and Alzheimer's disease.100–103 Cortisol levels can vary widely from patient to patient and change continuously, making continuous monitoring important in identifying changes in physiology that may indicate the disease state. The device shown in Fig. 3(h) features a graphene-based sensor that is functionalized with cortisol monoclonal antibodies (C-Mab), which act as a transducer to convert interaction between cortisol and C-Mab into changes in resistance that can be detected by the analog front end of the NFC chip. The sensor features a limit of detection of 10 pg/ml, well below the cortisol concentration in tears (1–40 ng/ml) with a sensitivity of 1.84 ng/ml. Results from in vivo testing is shown in Fig. 3(i) from both the right and left eye of a subject at 5-min intervals during a 30-min collection period. Both devices provide similar readouts for cortisol concentrations, indicating little sensor to sensor variance.

NFC-based communication and powering for wearable systems, while having robust pre-existing infrastructure and development, are unfavorable for many long-term wearable systems as they require close proximity to a transmission device for powering and data readout.104 Utilization of biofuel cells to convert sweat to usable electronic energy provides a potential avenue for applications that require operation outside of existing infrastructure. The device illustrated in Fig. 3(j) shows one such system66 capable of measuring key metabolic biomarkers. The device shown in Fig. 3(k) is comprised of a biofuel cell array with an energy density of 3.6 mW cm−2 in untreated human sweat samples and good long-term stability over 2000 cycles. Collection of urea and NH4+ concentrations were carried out using electrochemical patches based on ion-selective electrodes with enzymatic layers and can measure concentrations of 2.5–40 mM for both metabolites. Validation of device operation was carried out during a stationary biking exercise with data presented in Fig. 3(l). As expected, a decrease in urea and NH4+ concentrations is observed during the exercise period, which then stabilized after conclusion of cycling.

Wireless and battery-free biochemical sensors highlight an area of development with potentially high impact if device architectures allow for chronic recording capability that would otherwise require blood draw and laboratory testing, which is often a barrier to preventative measures that results in late diagnosis105 and limited metrics for continuous disease management and care.106,107

CURRENT LIMITATIONS OF WEARABLE DEVICES

The devices discussed in this review feature advances in materials science,5,32,44,108,117 electronics,7,109–114 and wireless power transfer115–121 to enable wireless and battery-free device formfactors with enhanced sensing capabilities to extract high fidelity biosignals. The goal of these devices is often to expand sensing functionality while improving user comfort and compliance with the hope to increase device acceptance. While for some applications such as screening and some diagnostic applications operating times are well below 1 week, where current schemes offer significant advantages over contemporary approaches, chronic operation (greater than 2 weeks at a time) has yet to be achieved. The significance of this chronic operation is progression toward the goal of continuous multimodal monitoring to enable digital medicine,122,123 namely, early automated diagnosis,124–128 personalized therapeutics,129–131 and individualized chronic care approaches.132

Battery-powered wearable systems, such as smartwatches or fitness trackers, offer a low barrier of entry to the consumer market, however, they incur penalties in sensing quality, useability, and user compliance.133,134 These issues are illustrated in Fig. 4(a). During normal device operation, there are frequent periods of biosignal interruption due to motion artifacts associated with the mass of the battery and formfactors that result in lack of conformality to the sensing target. Often, sensors are housed in large, rigid containers with masses ranging from 30 to 350 g, where rapid movement can disrupt the sensing interface.135 Utilization of a finite batteries requires the need for daily charging periods where devices must be removed, resulting in prolonged periods of data loss and increased chances of user noncompliance. This is compounded by device removal during certain activities such as sleep or hot weather due to user discomfort associated with the large device formfactor. Additionally, sensing regions are constrained to a small surface, typically on a peripheral appendage, which limits the sensor functionality and fidelity while decreasing physiological relavancy.136,137 Combined with other subjective requirements for user acceptance, such as discreet wearability and perceived value, result in underperforming user compliance, even despite initial acceptance success. These disruptions result in unrecorded biosignals that may hold key insight into underlying changes in subtle physiological parameters.

FIG. 4. Limitations of current wearable devices for biosensing applications. (a) Illustration showing conventional wrist worn wearable systems during operation. (b) Illustration of wearables utilizing adhesive interfaces during operation with key limitations in epidermal turnover. (Figure not reproduced here; see the original article.)

Current behavioral research suggests that ease of use, among other factors, played a role in low user acceptance of wearable systems over time.19,31,138 Studies also found large portions of daily data are low fidelity, which limits the scope and data aggregation capabilities restricting wholistic view of physiological phenomena.

Epidermal devices that provide skin-like mechanics, low dimensional profiles, and wireless power transfer functionalities enable high-fidelity biosignal acquisition by removal of weight associated with large battery-powered supplies with the ability to be deployed virtually anywhere on the body. Devices of these form factors, however, are insufficient to meet the demands of chronic data recording due to their inconsistency of power delivery to the system and their use of adhesive-based application for epidermal contact. The shortcomings of these devices are summarized in Fig. 4(b). Epidermal turnover, characterized by the cell renewal of the stratum corneum, is a barrier to longevity of such a device, as it frustrates the sensing interface and renders the adhesive bond to the skin nonfunctional, prohibiting recording or stimulation beyond 7–14 days depending on the skin renewal rate and location of the device.139

This physiology confines the use of adhesive based devices to acute applications or requires frequent renewal of the adhesive, which, for example, in a hospital setting is completely acceptable; however, it is less appealing for at-home diagnostic applications. Additionally in some cases, the utilization of strong adhesives may bar users from utilizing the device due to skin sensitivity,140 while the requirement for periodic replacement adds further burden to the user, which may affect long-term compliance and interrupt period of data collection.

OPPORTUNITIES FOR LONG-TERM WEARABLE DEVICES

To overcome user compliance challenges while providing long-term uninterrupted streams of high-fidelity data, a new class of wearable systems is needed. These devices must provide a robust platform that features body-like mechanical properties with high-fidelity sensing capabilities, long-range power transfer capabilities that enable reliable device operation without constraints of short-distance power transfer techniques, and miniaturized electronics that provide the uncompromised system function with low-profile and small footprint, in a package that enhances the user experience to the point that perceived value from the data far outweighs the burden of wearing a device. An example of such a device class called a biosymbiotic device is featured in Fig. 5(a).47 Devices are designed utilizing 3D scanning techniques141–145 to collect the users' topological data to tailor device mechanics and sensing capabilities directly to applications and need of the individual user. The device is fabricated using a 3D printed thermoplastic polyurethane (TPU) material that is digitally manufactured tailored to the users unique physiology.47 Embedded in the mesh are electronic systems [see Fig. 5(b)], which provide multimodal function while maintaining a low mechanical profile. Topological control offered by 3D printing allows for tuning of discrete and bulk mechanics, which enables epidermis like device mechanics and facilitates design of electromagnetics to optimize energy harvesting capabilities. A block diagram detailing the device operation principle is shown in Fig. 5(c). The device utilizes RF power transfer at 915 MHz to recharge the system wirelessly. Power harvested from the on-body antenna is directed to a power management system, which stores excess energy in a supercapacitor or miniaturized battery. The stored energy is used to power a BLE SoC, which collects information from peripheral sensors and digitally communicates data to a user interface for data analysis and storage.

FIG. 5. Long-term wearable sensing devices: (a) image showing biosymbiotic device for the biceps with inset illustrating the personalized digital design and fabrication process. (b) Layered schematic of biosymbiotic devices. (c) Functional diagram of the operating principle. (d) Realtime recording of body temperature collected from the axilla region during sitting (white) and walking (red). (e) Graph showing cyclic response of the 3D printed strain gauge during 16 N of applied stress (red) and corresponding change in resistance (black). (f) Graph showing lower leg acceleration of the biosymbiotic device (black) and gold standard (red) during a stationary jump. (g) Continuous data and sample global positioning system (GPS) mapping from a 7-day recording of body temperature and muscular strain captured by a biosymbiotic device worn on the proximal bicep. Adapted from Tucker et al., Sci. Adv. 7, eabj3269 (2021). Copyright 2021 Authors, licensed under a Creative Commons Attribution (CC BY) license.47 (Figure not reproduced here; see the original article.)

The conformality and mechanical profile of the device enables multimodal sensing capabilities matching or exceeding and expanding the current gold standard in battery-powered wearable systems. This has been demonstrated with several sensing capabilities including sub-millikelvin thermography, muscular deformation, and high-precision inertial measurements. Figure 5(d) shows the sub millikelvin resolution temperature sensor realized in a 2.5 mm node (shown in the inset, balanced on finger). The low thermal mass of the device enables fast response to small changes in the surface body temperature that enables detection of physiological changes, such as the difference in sitting and moderately paced walking, with axilla skin temperature change of less than 1 °C per event. Fidelity shown with this device class can provide valuable insight into acute or subtle variations indicating onset of disease.91,146–152

The circumferential fit and use of 3D printing also enables unique sensing capabilities that are currently not possible with conventional devices. One such modality is presented in Fig. 5(e), where a 3D printed, conductive TPU is used as a strain gauge to measure muscular deformation during activity. User specific placement and design can also increase signal fidelity. The graph in Fig. 5(e) shows the cyclic response of the strain gauge compared to input strain suitable for quantification of muscular deformation. The imperceptible weight (<500 mg) of the device also allows for highly accurate inertial measurements [see Fig. 5(f)]. A high-performance (IMU) realized in a 4 mm diameter node is compared to the gold standard, battery-powered system that is used for in-clinic assessment. The graph shows a subject performing a jump, in which the gold standard device shows motion artifacts due to device bulk inertia while the conformal system shows no motion artifacts. Removal of motion artifacts both increase data relevancy and reduce gaps in usable data, yielding accurate, long-term data collection capabilities.153,154

Advances of biosymbiotic electronics enable continuous streams of high-fidelity biosignals due to the ability for the system to wirelessly recharge without user interaction with charging infrastructure. This allows for previously untapped insight into several physiological processes that require continuous examination over extended periods demonstrated in Fig. 5(g). In the experiment, wireless power transmitters are set up in locations with high temporal occupancy to facilitate wireless power transfer. The plots demonstrate continuous acquisition of bicep deformation and core body temperature over a week-long study. Clear peaks of muscular deformation frequency and circadian rhythm can be observed correlating with logged activity and periods of rest. Data collected in this method will provide users with insight that is unattainable with the current standard in wearable technology sensing.

OPPORTUNITIES FOR ARTIFICIAL INTELLIGENCE AS MEANS OF ON-SENSOR AUTOMATED DATA PROCESSING

Wearable sensors can provide continuous, noninvasive, real-time monitoring of a wide range of physiological parameters. However, most of the available sensors are considered data collectors and/or alerting units with limited processing capabilities. Artificial intelligence (AI) offers a new path to turn biosensors into smart computational units, capable of making autonomous decisions and on-site detection/diagnosis, which is especially relevant to continuously recording devices such as biosymbiotic electronics. Local computation presents many opportunities in terms of data safety, latency,155,156 power consumption,157,158 personalized treatments, and data privacy and security155,156 [Fig. 6(a)]. Currently, wearable sensors are typically connected to another master device, usually a smartphone, for analytic purposes. This increases the risk compromised data safety and confidentiality because raw data are sent over the air. Processing the collected data on-device reduces privacy concerns and other cybersecurity threats. Additionally, sending data to the smartphone/cloud causes undesired delay and generally is inefficient due to relatively large power consumption of wireless radios. Conducting on-device machine learning (ML) and real-time execution reduces the data transmission rate, data latencies, and has the potential to reduce power consumption, especially for chronic recording with high sampling rates.

FIG. 6. Embedded artificial intelligence. (a) Advantages of embedded AI biosensors. (b) Block diagram of functional components of wearable devices with embedded AI. (c) Workflow for training and testing Machine learning models. (d) Graph showing the motor recovery trajectory using wearable smart biosensors.159 Reproduced with permission from Adans-Dester et al., npj Digital Med. 3, 1–10 (2020). Copyright 2020 Authors, licensed under a Creative Commons Attribution (CC BY) license. (Figure not reproduced here; see the original article.)

A wearable AI system usually consists of wearable sensors, analog front-end circuit responsible for amplifying, filtering, and signal conditioning the collected raw data from the sensors and a microcontroller used as the central processor, as shown in Fig. 6(b). With the emergence of on chip ML hardware in small packages156 and with low power consumption (TinyML paradigm), the AI algorithm can be executed on the system on a chip where event detection, feature extraction, and prediction can be computed. The regression/classification results can be sent wirelessly to a computer or smartphone for notification, offering tremendous opportunity for the device classes discussed in this review.

To train and test the regression/classification model, the following workflow, shown in Fig. 6(c), must be implemented for each sensor. Preprocessing of raw sensor data is usually required. Data compression, baseline drift removal, normalization, transformations, and other system-specific preprocessing methods are included. The processed data are then divided into training (approximately 60%), validation (20%), and testing (20%) sets.160 The training set is used to create the model and define the best algorithm hyperparameters. The validation set is used to tune these hyperparameters, and the testing set is utilized to evaluate the performance of the model. Prior to creating a model, feature extraction techniques are utilized to minimize the number of input variables. The reduction of the number of input variable results in reducing the computational cost of modeling and, in some situations, enhancing the model's performance.160 For wearable systems that are limited in computational resources, the model training is performed off-line first. The trained model is then embedded inside the microcontroller. On the microcontroller, the model is used to perform inference, making the wearable system a platform capable of making autonomous decisions.

Observing, classifying, and assessing human gestures/movements,161–163 predicting species or concentration of analytes, detecting arrhythmias,164 and enabling precision rehabilitation interventions are enabled with AI. An example of these capabilities is given by Dester et al.159 that use wearable accelerometer sensors placed on the arm, forearm, and fingers to assess the upper-limb motor function recovery after traumatic brain injury (TBI) or stroke. The data were collected from 37 patients (16 stroke survivor and 21 TBI survivor) during the performance of functional motor tasks. The data are then processed using ML techniques to estimate clinical scores measuring motor impairments and movement quality [e.g., the upper limb Fugl-Meyer assessment and the Functional Ability Scale]. Figure 6(d) shows the data collected from a patient during 36-week intervention. After 18 weeks, clinical scores are estimated using a ML algorithm. These scores characterize the motor recovery trajectory seen in response to the intervention during these 18 weeks [orange circles in Fig. 6(d)]. To predict the patient response to this intervention for the upcoming 18 weeks [green circles in Fig. 6(d)], the estimated clinical scores are used in conjunction with the clinical phenotype as inputs to the Gaussian process regression model (ML algorithm). Rehabilitation professionals can utilize these data to see if the patient is responding appropriately to the current intervention or if the intervention plan needs to be adjusted, hence providing patient-specific therapies highlighting the potential of AI in aiding diagnosis and therapy. It is important to note that the AI analysis was performed offline and not on the device; however, with suitable wearable and remote platforms, completely autonomous operation is viable with the latest generation of SoC.

DISCUSSION

Wearable medical devices for the extraction of high-fidelity biosignals are pivotal to the realization of digital medicine, where technology integrates with the human body and utilizes continuous data collection and advances in AI for treatment, diagnosis, and ultimately prevention of disease. Requirements for this paradigm include wearable devices that can be worn continuously to provide uninterrupted steams of clinical grade biosignals, while AI is deployed to identify trends and markers, which may indicate disease onset or changes in underlying physiology. The development of AI has greatly outpaced wearable technology for the realization of this goal. Current wrist band type wearable devices are inadequate due to their low-fidelity sensing capabilities and challenges for long-term wearability, which include both aspects of formfactors and issues with long-term user acceptance and compliance.

The emergence of chronically wearable wireless and battery-free devices provides an appealing alternative to standard wearable devices, as they have improved sensing fidelity and expand capabilities towards biosignals that previously required clinic-based wired setups. Additionally, materials and concepts used for this device class improve long-term wearability through reduction of bulk and introduction of overall soft mechanics. Despite this, many demonstrations have been limited to short-term and specific applications with day long duration due to natural physiological processes such as epidermal turnover. Further work geared toward demonstrations of chronically wearable devices in dynamic settings with high-fidelity sensing capabilities is needed. Successful implementation of on-board AI capabilities on these devices will unlock the full potential with broad applications among various disease archetypes. Specifically, these capabilities can improve diagnosis and monitoring of chronic diseases such as aging related frailty,165 chronic obstructive pulmonary disease,166 and mental health disorders.167,168 The development of these devices must also keep user acceptance models in mind to ensure successful translation and deployment in a large population cross section.

Acknowledgements

ACKNOWLEDGMENTSWe acknowledge support from the Department of Biomedical Engineering at the University of Arizona. T.S. and P.G. acknowledge support from the Flinn Foundation Translational Bioscience Seed Grant Pilot Program. T.S. acknowledges support from the National Science Foundation I-Corp program.

References

  1. P. Castillejo , J.-F. Martinez , J. Rodriguez-Molina , and A. Cuerva , “ Integration of wearable devices in a wireless sensor network for an E-health application,” IEEE Wireless Commun. 20, 38–49 (2013).10.1109/MWC.2013.6590049 doi:10.1109/MWC.2013.6590049
  2. M. Billinghurst and T. Starner , “ Wearable devices: New ways to manage information,” Computer 32, 57–64 (1999).10.1109/2.738305 doi:10.1109/2.738305
  3. M. S. Patel , D. A. Asch , and K. G. Volpp , “ Wearable devices as facilitators, not drivers, of health behavior change,” JAMA 313, 459–460 (2015).10.1001/jama.2014.1478125569175 doi:10.1001/jama.2014.14781 PubMed
  4. D. Son et al., “ Multifunctional wearable devices for diagnosis and therapy of movement disorders,” Nat. Nanotechnol. 9, 397–404 (2014).10.1038/nnano.2014.3824681776 doi:10.1038/nnano.2014.38 PubMed
  5. T. R. Ray et al., “ Bio-integrated wearable systems: A comprehensive review,” Chem. Rev. 119, 5461 (2019).10.1021/acs.chemrev.8b0057330689360 doi:10.1021/acs.chemrev.8b00573 PubMed
  6. J. R. Windmiller and J. Wang , “ Wearable electrochemical sensors and biosensors: A review,” Electroanalysis 25, 29–46 (2013).10.1002/elan.201200349 doi:10.1002/elan.201200349
  7. J. Heikenfeld et al., “ Wearable sensors: Modalities, challenges, and prospects,” Lab Chip 18, 217–248 (2018).10.1039/C7LC00914C29182185PMC5771841 doi:10.1039/C7LC00914C PubMed
  8. F. D. Davis , “ Perceived usefulness, perceived ease of use, and user acceptance of information technology,” MIS Q. 13, 319–340 (1989).10.2307/249008 doi:10.2307/249008
  9. V. Venkatesh , M. G. Morris , G. B. Davis , and F. D. Davis , “ User acceptance of information technology: Toward a unified view,” MIS Q. 27, 425–478 (2003).10.2307/30036540 doi:10.2307/30036540
  10. H. S. Chang , S. C. Lee , and Y. G. Ji , “ Wearable device adoption model with TAM and TTF,” Int. J. Mobile Commun. 14, 518–537 (2016).10.1504/IJMC.2016.078726 doi:10.1504/IJMC.2016.078726
  11. S. Ozkan-Yildirim and T. Pancar , “ Smart wearable technology for health tracking: What are the factors that affect their use?,” in IoT in Healthcare and Ambient Assisted Living ( Springer, 2021), pp. 165–199.
  12. E. Park , “ User acceptance of smart wearable devices: An expectation-confirmation model approach,” Telematics Inf. 47, 101318 (2020).10.1016/j.tele.2019.101318 doi:10.1016/j.tele.2019.101318
  13. A. Spagnolli , E. Guardigli , V. Orso , A. Varotto , and L. Gamberini , “ Measuring user acceptance of wearable symbiotic devices: Validation study across application scenarios,” in International Workshop on Symbiotic Interaction ( Springer, 2015), pp. 87–98.
  14. V. G. Motti and K. Caine , “ Human factors considerations in the design of wearable devices,” in Proceedings of the Human Factors and Ergonomics Society Annual Meeting ( SAGE Publications, 2014), Vol. 58, pp. 1820–1824.
  15. O. El-Gayar , T. Nasralah , and A. Elnoshokaty , “ Wearable devices for health and wellbeing: Design Insights from Twitter,” in Proceedings of the 52nd Hawaii International Conference on System Sciences, Grand Wailea, Hawaii, 8–11 January 2019 ( HICSS, 2019).
  16. J.-Y. Jeong and T.-W. Roh , “ The intention of using wearable devices: Based on modified technology acceptance model,” J. Digital Convergence 15, 205–212 (2017).10.14400/JDC.2017.15.4.205 doi:10.14400/JDC.2017.15.4.205
  17. J. Li , Q. Ma , A. H. S. Chan , and S. S. Man , “ Health monitoring through wearable technologies for older adults: Smart wearables acceptance model,” Appl. Ergon. 75, 162–169 (2019).10.1016/j.apergo.2018.10.00630509522 doi:10.1016/j.apergo.2018.10.006 PubMed
  18. K. J. Kim and D.-H. Shin , “ An acceptance model for smart watches: Implications for the adoption of future wearable technology,” Internet Res. 25, 527 (2015).10.1108/IntR-05-2014-0126 doi:10.1108/IntR-05-2014-0126
  19. Y. Gao , H. Li , and Y. Luo , “ An empirical study of wearable technology acceptance in healthcare,” Ind. Manag. Data Syst. 115, 1704 (2015).10.1108/IMDS-03-2015-0087 doi:10.1108/IMDS-03-2015-0087
  20. S. M. Lee and D. Lee , “ Healthcare wearable devices: An analysis of key factors for continuous use intention,” Serv. Bus. 14, 503–531 (2020).10.1007/s11628-020-00428-3 doi:10.1007/s11628-020-00428-3
  21. Y. Jung , S. Kim , and B. Choi , “ Consumer valuation of the wearables: The case of smartwatches,” Comput. Hum. Behav. 63, 899–905 (2016).10.1016/j.chb.2016.06.040 doi:10.1016/j.chb.2016.06.040
  22. J. J. Ferreira , C. I. Fernandes , H. G. Rammal , and P. M. Veiga , “ Wearable technology and consumer interaction: A systematic review and research agenda,” Comput. Hum. Behav. 118, 106710 (2021).10.1016/j.chb.2021.106710 doi:10.1016/j.chb.2021.106710
  23. D. Magni , V. Scuotto , A. Pezzi , and M. Del Giudice , “ Employees' acceptance of wearable devices: Towards a predictive model,” Technol. Forecast. Soc. Change 172, 121022 (2021).10.1016/j.techfore.2021.121022 doi:10.1016/j.techfore.2021.121022
  24. F. B. Insights , “ Fitness tracker market size, share & COVID-19 impact analysis,” Healthcare IT Market Research Report No. BI103358 (2020).
  25. R. Chandrasekaran , V. Katthula , and E. Moustakas , “ Patterns of use and key predictors for the use of wearable health care devices by US adults: Insights from a National Survey,” J. Med. Internet Res. 22, e22443 (2020).10.2196/2244333064083PMC7600024 doi:10.2196/22443 PubMed
  26. A. Channa , N. Popescu , J. Skibinska , and R. Burget , “ The rise of wearable devices during the COVID-19 pandemic: A systematic review,” Sensors 21, 5787 (2021).10.3390/s2117578734502679PMC8434481 doi:10.3390/s21175787 PubMed
  27. D. Ledger and D. McCaffrey , “ Inside wearables: How the science of human behavior change offers the secret to long-term engagement,” Endeav. Partners 200, 1 (2014), available at http://endeavourpartners.net/assets/Wearables-and-the-Science-of-Human-Behavior-Change-EP4.pdf.
  28. K. Mercer et al., “ Acceptance of commercially available wearable activity trackers among adults aged over 50 and with chronic illness: A mixed-methods evaluation,” JMIR mHealth uHealth 4, e7 (2016).10.2196/mhealth.422526818775PMC4749845 doi:10.2196/mhealth.4225 PubMed
  29. J. Xie et al., “ Evaluating the validity of current mainstream wearable devices in fitness tracking under various physical activities: Comparative study,” JMIR mHealth uHealth 6, e94 (2018).10.2196/mhealth.975429650506PMC5920198 doi:10.2196/mhealth.9754 PubMed
  30. D. Wen , X. Zhang , X. Liu , and J. Lei , “ Evaluating the consistency of current mainstream wearable devices in health monitoring: A comparison under free-living conditions,” J. Med. Internet Res. 19, e68 (2017).10.2196/jmir.687428270382PMC5360892 doi:10.2196/jmir.6874 PubMed
  31. H. Yang , J. Yu , H. Zo , and M. Choi , “ User acceptance of wearable devices: An extended perspective of perceived value,” Telematics Inf. 33, 256–269 (2016).10.1016/j.tele.2015.08.007 doi:10.1016/j.tele.2015.08.007
  32. L. Wang , Z. Lou , K. Jiang , and G. Shen , “ Bio-multifunctional smart wearable sensors for medical devices,” Adv. Intell. Syst. 1, 1900040 (2019).10.1002/aisy.201900040 doi:10.1002/aisy.201900040
  33. T. Loncar-Turukalo , E. Zdravevski , J. Machado da Silva , I. Chouvarda , and V. Trajkovik , “ Literature on wearable technology for connected health: Scoping review of research trends, advances, and barriers,” J. Med. Internet Res. 21, e14017 (2019).10.2196/1401731489843PMC6818529 doi:10.2196/14017 PubMed
  34. Y. Khan et al., “ Flexible hybrid electronics: Direct interfacing of soft and hard electronics for wearable health monitoring,” Adv. Funct. Mater. 26, 8764–8775 (2016).10.1002/adfm.201603763 doi:10.1002/adfm.201603763
  35. X. Huang et al., “ Materials strategies and device architectures of emerging power supply devices for implantable bioelectronics,” Small 16, 1902827 (2019).10.1002/smll.20190282731513333 doi:10.1002/smll.201902827 PubMed
  36. S.-H. Sunwoo , K.-H. Ha , S. Lee , N. Lu , and D.-H. Kim , “ Wearable and implantable soft bioelectronics: Device designs and material strategies,” Annu. Rev. Chem. Biomol. Eng. 12, 359–391 (2021).10.1146/annurev-chembioeng-101420-02433634097846 doi:10.1146/annurev-chembioeng-101420-024336 PubMed
  37. W.-J. Song et al., “ Recent progress in stretchable batteries for wearable electronics,” Batteries Supercaps 2, 181–199 (2019).10.1002/batt.201800140 doi:10.1002/batt.201800140
  38. C. Wang , T. He , J. Cheng , Q. Guan , and B. Wang , “ Bioinspired interface design of sewable, weavable, and washable fiber zinc batteries for wearable power textiles,” Adv. Funct. Mater. 30, 2004430 (2020).10.1002/adfm.202004430 doi:10.1002/adfm.202004430
  39. Z. Wu et al., “ Carbon-nanomaterial-based flexible batteries for wearable electronics,” Adv. Mater. 31, 1800716 (2019).10.1002/adma.20180071630680813 doi:10.1002/adma.201800716 PubMed
  40. T. Stuart , L. Cai , A. Burton , and P. Gutruf , “ Wireless and battery-free platforms for collection of biosignals,” Biosens. Bioelectron. 178, 113007 (2021).10.1016/j.bios.2021.11300733556807PMC8112193 doi:10.1016/j.bios.2021.113007 PubMed
  41. X. Yu et al., “ Skin-integrated wireless haptic interfaces for virtual and augmented reality,” Nature 575, 473–479 (2019).10.1038/s41586-019-1687-031748722 doi:10.1038/s41586-019-1687-0 PubMed
  42. D. Barman , A. W. Reza , N. Kumar , M. E. Karim , and A. B. Munir , “ Wireless powering by magnetic resonant coupling: Recent trends in wireless power transfer system and its applications,” Renewable Sustainable Energy Rev. 51, 1525–1552 (2015).10.1016/j.rser.2015.07.031 doi:10.1016/j.rser.2015.07.031
  43. J. A. Elder and D. F. Cahill , Biological Effects of Radiofrequency Radiation ( Health Effects Research Laboratory, Office of Research and Development, 1984).
  44. J. Kim et al., “ Epidermal electronics with advanced capabilities in near-field communication,” Small 11, 906–912 (2015).10.1002/smll.20140249525367846 doi:10.1002/smll.201402495 PubMed
  45. X. Tian et al., “ Wireless body sensor networks based on metamaterial textiles,” Nat. Electron. 2, 243–251 (2019).10.1038/s41928-019-0257-7 doi:10.1038/s41928-019-0257-7
  46. Y. Jiang , K. Pan , T. Leng , and Z. Hu , “ Smart textile integrated wireless powered near field communication body temperature and sweat sensing system,” IEEE J. Electromagn. RF Microwaves Med. Biol. 4, 164–170 (2020).10.1109/JERM.2019.2929676 doi:10.1109/JERM.2019.2929676
  47. S. Tucker et al., “ Biosymbiotic, personalized, and digitally manufactured wireless devices for indefinite collection of high-fidelity biosignals,” Sci. Adv. 7, eabj3269 (2021).10.1126/sciadv.abj326934623919PMC8500520 doi:10.1126/sciadv.abj3269 PubMed
  48. X. Huang et al., “ Epidermal radio frequency electronics for wireless power transfer,” Microsyst. Nanoeng. 2, 16052 (2016).10.1038/micronano.2016.5231057838PMC6444737 doi:10.1038/micronano.2016.52 PubMed
  49. J. S. Ho et al., “ Self-tracking energy transfer for neural stimulation in untethered mice,” Phys. Rev. Appl. 4, 24001 (2015).10.1103/PhysRevApplied.4.024001 doi:10.1103/PhysRevApplied.4.024001
  50. K. Yu et al., “ Organic photovoltaics: Toward self-powered wearable electronics,” Proc. IEEE 107, 2137–2154 (2019).10.1109/JPROC.2019.2929797 doi:10.1109/JPROC.2019.2929797
  51. H. K. H. Lee et al., “ Organic photovoltaic cells–promising indoor light harvesters for self-sustainable electronics,” J. Mater. Chem. A 6, 5618–5626 (2018).10.1039/C7TA10875C doi:10.1039/C7TA10875C
  52. S. Lee , Y. Lee , J. Park , and D. Choi , “ Stitchable organic photovoltaic cells with textile electrodes,” Nano Energy 9, 88–93 (2014).10.1016/j.nanoen.2014.06.017 doi:10.1016/j.nanoen.2014.06.017
  53. S. Park et al., “ Self-powered ultra-flexible electronics via nano-grating-patterned organic photovoltaics,” Nature 561, 516 (2018).10.1038/s41586-018-0536-x30258137 doi:10.1038/s41586-018-0536-x PubMed
  54. N. Zhang et al., “ A wearable all‐solid photovoltaic textile,” Adv. Mater. 28, 263–269 (2016).10.1002/adma.20150413726544099 doi:10.1002/adma.201504137 PubMed
  55. S. H. Cho et al., “ Plasmonically engineered textile polymer solar cells for high-performance, wearable photovoltaics,” ACS Appl. Mater. Interfaces 11, 20864–20872 (2019).10.1021/acsami.9b0504831144506 doi:10.1021/acsami.9b05048 PubMed
  56. J. Liu , Y. Li , S. Yong , S. Arumugam , and S. Beeby , “ Flexible printed monolithic-structured solid-state dye sensitized solar cells on woven glass fibre textile for wearable energy harvesting applications,” Sci. Rep. 9, 1362 (2019).10.1038/s41598-018-37590-830718574PMC6362153 doi:10.1038/s41598-018-37590-8 PubMed
  57. H. Jinno et al., “ Stretchable and waterproof elastomer-coated organic photovoltaics for washable electronic textile applications,” Nat. Energy 2, 780–785 (2017).10.1038/s41560-017-0001-3 doi:10.1038/s41560-017-0001-3
  58. F.-R. Fan , Z.-Q. Tian , and Z. L. Wang , “ Flexible triboelectric generator,” Nano Energy 1, 328–334 (2012).10.1016/j.nanoen.2012.01.004 doi:10.1016/j.nanoen.2012.01.004
  59. C. Ning et al., “ Washable textile-structured single-electrode triboelectric nanogenerator for self-powered wearable electronics,” J. Mater. Chem. A 6, 19143–19150 (2018).10.1039/C8TA07784C doi:10.1039/C8TA07784C
  60. K. Xia et al., “ A high-output triboelectric nanogenerator based on nickel–copper bimetallic hydroxide nanowrinkles for self-powered wearable electronics,” J. Mater. Chem. A 8, 25995–26003 (2020).10.1039/D0TA09440D doi:10.1039/D0TA09440D
  61. S. Yu et al., “ Wireless battery-free wearable sweat sensor powered by human motion,” Sci. Adv. 6, eaay9842 (2021).10.1126/sciadv.aay9842PMC752722532998888 doi:10.1126/sciadv.aay9842 PubMed
  62. G. Zhu et al., “ A shape‐adaptive thin‐film‐based approach for 50% high‐efficiency energy generation through micro‐grating sliding electrification,” Adv. Mater. 26, 3788–3796 (2014).10.1002/adma.20140002124692147 doi:10.1002/adma.201400021 PubMed
  63. Y. Xie et al., “ Grating‐structured freestanding triboelectric‐layer nanogenerator for harvesting mechanical energy at 85% total conversion efficiency,” Adv. Mater. 26, 6599–6607 (2014).10.1002/adma.20140242825156128 doi:10.1002/adma.201402428 PubMed
  64. W. Tang et al., “ Liquid‐metal electrode for high‐performance triboelectric nanogenerator at an instantaneous energy conversion efficiency of 70.6%,” Adv. Funct. Mater. 25, 3718–3725 (2015).10.1002/adfm.201501331 doi:10.1002/adfm.201501331
  65. A. J. Bandodkar et al., “ Sweat-activated biocompatible batteries for epidermal electronic and microfluidic systems,” Nat. Electron. 3, 554 (2020).10.1038/s41928-020-0443-7 doi:10.1038/s41928-020-0443-7
  66. Y. Yu et al., “ Biofuel-powered soft electronic skin with multiplexed and wireless sensing for human-machine interfaces,” Sci. Rob. 5, 1–14 (2020).10.1126/scirobotics.aaz7946PMC732632832607455 doi:10.1126/scirobotics.aaz7946 PubMed
  67. A. H. Talkhooncheh et al., “ A biofuel-cell-based energy harvester with 86% peak efficiency and 0.25-V minimum input voltage using source-adaptive MPPT,” IEEE J. Solid-State Circuits 56, 715 (2020).10.1109/JSSC.2020.3035491 doi:10.1109/JSSC.2020.3035491
  68. Y. Wang , Y. Shi , D. Mei , and Z. Chen , “ Wearable thermoelectric generator to harvest body heat for powering a miniaturized accelerometer,” Appl. Energy 215, 690–698 (2018).10.1016/j.apenergy.2018.02.062 doi:10.1016/j.apenergy.2018.02.062
  69. S. W. Lee et al., “ An electrochemical system for efficiently harvesting low-grade heat energy,” Nat. Commun. 5, 3942 (2014).10.1038/ncomms494224845707 doi:10.1038/ncomms4942 PubMed
  70. Q. Zhang , Y. Sun , W. Xu , and D. Zhu , “ Organic thermoelectric materials: Emerging green energy materials converting heat to electricity directly and efficiently,” Adv. Mater. 26, 6829–6851 (2014).10.1002/adma.20130537124687930 doi:10.1002/adma.201305371 PubMed
  71. V. Leonov and R. J. M. Vullers , “ Wearable electronics self-powered by using human body heat: The state of the art and the perspective,” J. Renewable Sustainable Energy 1, 62701 (2009).10.1063/1.3255465 doi:10.1063/1.3255465
  72. D.-L. Wen et al., “ Wearable multi-sensing double-chain thermoelectric generator,” Microsyst. Nanoeng. 6, 68 (2020).10.1038/s41378-020-0179-634567679PMC8433441 doi:10.1038/s41378-020-0179-6 PubMed
  73. V. Leonov et al., “ Wearable self-powered wireless devices with thermoelectric energy scavengers,” in 2nd European Conference & Exhibition on Integration Issues of Miniaturized Systems-MOMS, MOEMS, ICS and Electronic Components ( VDE, 2008), pp. 1–8.
  74. M. Thielen , L. Sigrist , M. Magno , C. Hierold , and L. Benini , “ Human body heat for powering wearable devices: From thermal energy to application,” Energy Convers. Manage. 131, 44–54 (2017).10.1016/j.enconman.2016.11.005 doi:10.1016/j.enconman.2016.11.005
  75. C. Pang et al., “ Highly skin-conformal microhairy sensor for pulse signal amplification,” Adv. Mater. 27, 634–640 (2015).10.1002/adma.20140380725358966 doi:10.1002/adma.201403807 PubMed
  76. M. K. Choi et al., “ Cephalopod-inspired miniaturized suction cups for smart medical skin,” Adv. Healthcare Mater. 5, 80–87 (2016).10.1002/adhm.20150028525989744 doi:10.1002/adhm.201500285 PubMed
  77. J. Kim , A. S. Campbell , B. E. F. de Ávila , and J. Wang , “ Wearable biosensors for healthcare monitoring,” Nat. Biotechnol. 37, 389–406 (2019).10.1038/s41587-019-0045-y30804534PMC8183422 doi:10.1038/s41587-019-0045-y PubMed
  78. D. Kireev et al., “ Fabrication, characterization and applications of graphene electronic tattoos,” Nat. Protoc. 16, 2395–2417 (2021).10.1038/s41596-020-00489-833846631 doi:10.1038/s41596-020-00489-8 PubMed
  79. W. Youhua et al., “ Electrically compensated, tattoo-like electrodes for epidermal electrophysiology at scale,” Sci. Adv. 6, eabd0996 (2022).10.1126/sciadv.abd0996PMC760883733097545 doi:10.1126/sciadv.abd0996 PubMed
  80. R. Lin et al., “ Wireless battery-free body sensor networks using near-field-enabled clothing,” Nat. Commun. 11, 444 (2020).10.1038/s41467-020-14311-231974376PMC6978350 doi:10.1038/s41467-020-14311-2 PubMed
  81. H. U. Chung et al., “ Skin-interfaced biosensors for advanced wireless physiological monitoring in neonatal and pediatric intensive-care units,” Nat. Med. 26, 418–429 (2020).10.1038/s41591-020-0792-932161411PMC7315772 doi:10.1038/s41591-020-0792-9 PubMed
  82. H. U. Chung et al., “ Binodal, wireless epidermal electronic systems with in-sensor analytics for neonatal intensive care,” Science 363, eaau0780 (2019).10.1126/science.aau078030819934PMC6510306 doi:10.1126/science.aau0780 PubMed
  83. S. R. Krishnan et al., “ Wireless, battery-free epidermal electronics for continuous, quantitative, multimodal thermal characterization of skin,” Small 14, 1–13 (2018).10.1002/smll.20180319230369049 doi:10.1002/smll.201803192 PubMed
  84. M. Broom , A. M. Dunk , and A.-L. E Mohamed , “ Predicting neonatal skin injury: The first step to reducing skin injuries in neonates,” Health Serv. Insights 12, 117863291984563 (2019).10.1177/1178632919845630PMC657289331236011 doi:10.1177/1178632919845630 PubMed
  85. S. R. Krishnan et al., “ Epidermal electronics for noninvasive, wireless, quantitative assessment of ventricular shunt function in patients with hydrocephalus,” Sci. Transl. Med. 10, eaat8437 (2018).10.1126/scitranslmed.aat843730381410 doi:10.1126/scitranslmed.aat8437 PubMed
  86. A. J. Bandodkar et al., “ Battery-free, skin-interfaced microfluidic/electronic systems for simultaneous electrochemical, colorimetric, and volumetric analysis of sweat,” Sci. Adv. 5, eaav3294 (2019).10.1126/sciadv.aav329430746477PMC6357758 doi:10.1126/sciadv.aav3294 PubMed
  87. A. Koh et al., “ A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat,” Sci. Transl. Med. 8, 366ra165 (2016).10.1126/scitranslmed.aaf2593PMC542909727881826 doi:10.1126/scitranslmed.aaf2593 PubMed
  88. Z. Sonner et al., “ The microfluidics of the eccrine sweat gland, including biomarker partitioning, transport, and biosensing implications,” Biomicrofluidics 9, 31301 (2015).10.1063/1.4921039PMC443348326045728 doi:10.1063/1.4921039 PubMed
  89. W. Gao et al., “ Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis,” Nature 529, 509 (2016).10.1038/nature1652126819044PMC4996079 doi:10.1038/nature16521 PubMed
  90. J. Choi , R. Ghaffari , L. B. Baker , and J. A. Rogers , “ Skin-interfaced systems for sweat collection and analytics,” Sci. Adv. 4, eaar3921 (2018).10.1126/sciadv.aar392129487915PMC5817925 doi:10.1126/sciadv.aar3921 PubMed
  91. J. T. Reeder et al., “ Waterproof, electronics-enabled, epidermal microfluidic devices for sweat collection, biomarker analysis, and thermography in aquatic settings,” Sci. Adv. 5, eaau6356 (2019).10.1126/sciadv.aau635630746456PMC6357724 doi:10.1126/sciadv.aau6356 PubMed
  92. J. Kim et al., “ Wearable smart sensor systems integrated on soft contact lenses for wireless ocular diagnostics,” Nat. Commun. 8, 14997 (2017).10.1038/ncomms1499728447604PMC5414034 doi:10.1038/ncomms14997 PubMed
  93. X. Wang et al., “ Sensitive colorimetric assay for uric acid and glucose detection based on multilayer-modified paper with smartphone as signal readout,” Anal. Bioanal. Chem. 410, 2647–2655 (2018).10.1007/s00216-018-0939-429455281 doi:10.1007/s00216-018-0939-4 PubMed
  94. M. Ku et al., “ Smart, soft contact lens for wireless immunosensing of cortisol,” Sci. Adv. 6, eabb2891 (2020).10.1126/sciadv.abb289132923592PMC7455488 doi:10.1126/sciadv.abb2891 PubMed
  95. J. Wang et al., “ Sustainably powering wearable electronics solely by biomechanical energy,” Nat. Commun. 7, 12744 (2016).10.1038/ncomms1274427677971PMC5052715 doi:10.1038/ncomms12744 PubMed
  96. W. Seung et al., “ Nanopatterned textile-based wearable triboelectric nanogenerator,” ACS Nano 9, 3501–3509 (2015).10.1021/nn507221f25670211 doi:10.1021/nn507221f PubMed
  97. C. Wu , A. C. Wang , W. Ding , H. Guo , and Z. L. Wang , “ Triboelectric nanogenerator: A foundation of the energy for the new era,” Adv. Energy Mater. 9, 1802906 (2019).10.1002/aenm.201802906 doi:10.1002/aenm.201802906
  98. J. Zhang , W. Hodge , C. Hutnick , and X. Wang , “ Noninvasive diagnostic devices for diabetes through measuring tear glucose,” J. Diabetes Sci. Technol. 5, 166–172 (2011).10.1177/19322968110050012321303640PMC3045221 doi:10.1177/193229681100500123 PubMed
  99. N. M. Farandos , A. K. Yetisen , M. J. Monteiro , C. R. Lowe , and S. H. Yun , “ Contact lens sensors in ocular diagnostics,” Adv. Healthcare Mater. 4, 792–810 (2015).10.1002/adhm.20140050425400274 doi:10.1002/adhm.201400504 PubMed
  100. E. R. De Kloet , M. Joëls , and F. Holsboer , “ Stress and the brain: From adaptation to disease,” Nat. Rev. Neurosci. 6, 463–475 (2005).10.1038/nrn168315891777 doi:10.1038/nrn1683 PubMed
  101. S. H. Sunwoo et al., “ Chronic and acute stress monitoring by electrophysiological signals from adrenal gland,” Proc. Natl. Acad. Sci. 116, 1146–1151 (2019).10.1073/pnas.180639211530617062PMC6347678 doi:10.1073/pnas.1806392115 PubMed
  102. L. Stojanovich , “ Stress and autoimmunity,” Autoimmun. Rev. 9, A271–A276 (2010).10.1016/j.autrev.2009.11.01419931651 doi:10.1016/j.autrev.2009.11.014 PubMed
  103. B. S. McEwen , “ Protective and damaging effects of stress mediators,” N. Engl. J. Med. 338, 171–179 (1998).10.1056/NEJM1998011533803079428819 doi:10.1056/NEJM199801153380307 PubMed
  104. Z. Lou , L. Li , L. Wang , and G. Shen , “ Recent progress of self‐powered sensing systems for wearable electronics,” Small 13, 1701791 (2017).10.1002/smll.20170179129076297 doi:10.1002/smll.201701791 PubMed
  105. S. F. Green , “ The cost of poor blood specimen quality and errors in preanalytical processes,” Clin. Biochem. 46, 1175–1179 (2013).10.1016/j.clinbiochem.2013.06.00123769816 doi:10.1016/j.clinbiochem.2013.06.001 PubMed
  106. R. Ghaffari , J. A. Rogers , and T. R. Ray , “ Recent progress, challenges, and opportunities for wearable biochemical sensors for sweat analysis,” Sens. Actuators, B 332, 129447 (2021).10.1016/j.snb.2021.129447PMC785365333542590 doi:10.1016/j.snb.2021.129447 PubMed
  107. A. J. Bandodkar , W. J. Jeang , R. Ghaffari , and J. A. Rogers , “ Wearable sensors for biochemical sweat analysis,” Annu. Rev. Anal. Chem. 12, 1–22 (2019).10.1146/annurev-anchem-061318-11491030786214 doi:10.1146/annurev-anchem-061318-114910 PubMed
  108. S. B. Kim et al., “ Soft, skin-interfaced microfluidic systems with wireless, battery-free electronics for digital, real-time tracking of sweat loss and electrolyte composition,” Small 14, 1802876 (2018).10.1002/smll.20180287630300469 doi:10.1002/smll.201802876 PubMed
  109. R. W. Keyes , “ Miniaturization of electronics and its limits,” IBM J. Res. Dev. 32, 84–88 (1988).10.1147/rd.321.0024 doi:10.1147/rd.321.0024
  110. M. Rasouli and L. S. J. Phee , “ Energy sources and their development for application in medical devices,” Expert Rev. Med. Devices 7, 693–709 (2010).10.1586/erd.10.2020822391 doi:10.1586/erd.10.20 PubMed
  111. E. Popovici , M. Magno , and S. Marinkovic , “ Power management techniques for wireless sensor networks: A review,” in 5th IEEE International Workshop on Advances in Sensors and Interfaces IWASI ( IEEE, 2013), pp. 194–198.
  112. E. P. Scilingo and G. Valenza , “ Recent advances on wearable electronics and embedded computing systems for biomedical applications,” Electronics 6, 12 (2017).10.3390/electronics6010012 doi:10.3390/electronics6010012
  113. M. M. Rodgers , V. M. Pai , and R. S. Conroy , “ Recent advances in wearable sensors for health monitoring,” IEEE Sens. J. 15, 3119–3126 (2014).10.1109/JSEN.2014.2357257 doi:10.1109/JSEN.2014.2357257
  114. S. R. Krishnan et al., “ Epidermal electronics: Wireless, battery-free epidermal electronics for continuous, quantitative, multimodal thermal characterization of skin (Small 47/2018),” Small 14, 1870226 (2018).10.1002/smll.20187022630369049 doi:10.1002/smll.201870226 PubMed
  115. J. Huang , Y. Zhou , Z. Ning , and H. Gharavi , “ Wireless power transfer and energy harvesting: Current status and future prospects,” IEEE Wireless Commun. 26, 163–169 (2019).10.1109/MWC.2019.1800378PMC706722532165868 doi:10.1109/MWC.2019.1800378 PubMed
  116. L. Xie , Y. Shi , Y. T. Hou , and A. Lou , “ Wireless power transfer and applications to sensor networks,” IEEE Wireless Commun. 20, 140–145 (2013).10.1109/MWC.2013.6590061 doi:10.1109/MWC.2013.6590061
  117. J. Kim et al., “ Miniaturized battery-free wireless systems for wearable pulse oximetry,” Adv. Funct. Mater. 27, 1604373 (2017).10.1002/adfm.20160437328798658PMC5545889 doi:10.1002/adfm.201604373 PubMed
  118. R. Want , “ Near field communication,” IEEE Pervasive Comput. 10, 4–7 (2011).10.1109/MPRV.2011.55 doi:10.1109/MPRV.2011.55
  119. H.-J. Kim et al., “ Review of near-field wireless power and communication for biomedical applications,” IEEE Access 5, 21264 (2017).10.1109/ACCESS.2017.2757267 doi:10.1109/ACCESS.2017.2757267
  120. F. Zhang , J. Liu , Z. Mao , and M. Sun , “ Mid-range wireless power transfer and its application to body sensor networks,” Open J. Appl. Sci. 2, 35 (2012).10.4236/ojapps.2012.21004 doi:10.4236/ojapps.2012.21004
  121. A. Salim and S. Lim , “ Recent advances in noninvasive flexible and wearable wireless biosensors,” Biosens. Bioelectron. 141, 111422 (2019).10.1016/j.bios.2019.11142231229794 doi:10.1016/j.bios.2019.111422 PubMed
  122. E. J. Topol , “ Transforming medicine via digital innovation,” Sci. Transl. Med. 2, 16cm4 (2010).10.1126/scitranslmed.3000484PMC375608820371472 doi:10.1126/scitranslmed.3000484 PubMed
  123. E. Elenko , L. Underwood , and D. Zohar , “ Defining digital medicine,” Nat. Biotechnol. 33, 456–461 (2015).10.1038/nbt.322225965750 doi:10.1038/nbt.3222 PubMed
  124. J. K. Sajeev , A. N. Koshy , and A. W. Teh , “ Wearable devices for cardiac arrhythmia detection: A new contender?,” Intern. Med. J. 49, 570–573 (2019).10.1111/imj.1427431083804 doi:10.1111/imj.14274 PubMed
  125. M. J. Rahman et al., “ Automated assessment of pulmonary patients using heart rate variability from everyday wearables,” Smart Health 15, 100081 (2020).10.1016/j.smhl.2019.100081 doi:10.1016/j.smhl.2019.100081
  126. J. Acharya and A. Basu , “ Deep neural network for respiratory sound classification in wearable devices enabled by patient specific model tuning,” IEEE Trans. Biomed. Circuits Syst. 14, 535–544 (2020).10.1109/TBCAS.2020.298117232191898 doi:10.1109/TBCAS.2020.2981172 PubMed
  127. S. Beniczky , I. Conradsen , O. Henning , M. Fabricius , and P. Wolf , “ Automated real-time detection of tonic-clonic seizures using a wearable EMG device,” Neurology 90, e428 (2018).10.1212/WNL.000000000000489329305441PMC5791791 doi:10.1212/WNL.0000000000004893 PubMed
  128. F. Rincón , P. R. Grassi , N. Khaled , D. Atienza , and D. Sciuto , “ Automated real-time atrial fibrillation detection on a wearable wireless sensor platform,” in 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society ( IEEE, 2012), pp. 2472–2475.10.1109/EMBC.2012.634646523366426 doi:10.1109/EMBC.2012.6346465 PubMed
  129. A. Palanica , M. J. Docktor , M. Lieberman , and Y. Fossat , “ The need for artificial intelligence in digital therapeutics,” Digital Biomarkers 4, 21–25 (2020).10.1159/00050686132399513PMC7204774 doi:10.1159/000506861 PubMed
  130. N. A. Patel and A. J. Butte , “ Characteristics and challenges of the clinical pipeline of digital therapeutics,” npj Digital Med. 3, 159 (2020).10.1038/s41746-020-00370-8PMC773351433311567 doi:10.1038/s41746-020-00370-8 PubMed
  131. J. S. Hong , C. Wasden , and D. H. Han , “ Introduction of digital therapeutics,” Comput. Methods Programs Biomed. 209, 106319 (2021).10.1016/j.cmpb.2021.10631934364181 doi:10.1016/j.cmpb.2021.106319 PubMed
  132. J. C. Kvedar , A. L. Fogel , E. Elenko , and D. Zohar , “ Digital medicine's march on chronic disease,” Nat. Biotechnol. 34, 239–246 (2016).10.1038/nbt.349526963544 doi:10.1038/nbt.3495 PubMed
  133. L. Menghini et al., “ Stressing the accuracy: Wrist‐worn wearable sensor validation over different conditions,” Psychophysiology 56, e13441 (2019).10.1111/psyp.1344131332802 doi:10.1111/psyp.13441 PubMed
  134. R. R. Kroll , J. G. Boyd , and D. M. Maslove , “ Accuracy of a wrist-worn wearable device for monitoring heart rates in hospital inpatients: A prospective observational study,” J. Med. Internet Res. 18, e253 (2016).10.2196/jmir.602527651304PMC5050383 doi:10.2196/jmir.6025 PubMed
  135. J. Liang et al., “ Usability study of mainstream wearable fitness devices: Feature analysis and system usability scale evaluation,” JMIR mHealth uHealth 6, e11066 (2018).10.2196/1106630409767PMC6250954 doi:10.2196/11066 PubMed
  136. J. Yao and S. Warren , “ A short study to assess the potential of independent component analysis for motion artifact separation in wearable pulse oximeter signals,” in 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference ( IEEE, 2006), pp. 3585–3588.10.1109/IEMBS.2005.161725617281001 doi:10.1109/IEMBS.2005.1617256 PubMed
  137. Y. Maeda , M. Sekine , and T. Tamura , “ Relationship between measurement site and motion artifacts in wearable reflected photoplethysmography,” J. Med. Syst. 35, 969–976 (2011).10.1007/s10916-010-9505-020703691 doi:10.1007/s10916-010-9505-0 PubMed
  138. T. Kim and W. Chiu , “ Consumer acceptance of sports wearable technology: The role of technology readiness,” Int. J. Sport. Mark. Spons. 20, 109–126 (2019).10.1108/IJSMS-06-2017-0050 doi:10.1108/IJSMS-06-2017-0050
  139. K. M. HALPRIN , “ Epidermal ‘turnover time’—A re‐examination,” Br. J. Dermatol. 86, 14–19 (1972).10.1111/j.1365-2133.1972.tb01886.x4551262 doi:10.1111/j.1365-2133.1972.tb01886.x PubMed
  140. L. McNichol , C. Lund , T. Rosen , and M. Gray , “ Medical adhesives and patient safety: State of the science consensus statements for the assessment, prevention, and treatment of adhesive-related skin injuries,” J. Wound Ostomy Continence Nurs. 40, 365–380 (2013).10.1097/WON.0b013e318299551623759927 doi:10.1097/WON.0b013e3182995516 PubMed
  141. A. Haleem and M. Javaid , “ Role of CT and MRI in the design and development of orthopaedic model using additive manufacturing,” J. Clin. Orthop. Trauma 9, 213–217 (2018).10.1016/j.jcot.2018.07.00230202151PMC6128794 doi:10.1016/j.jcot.2018.07.002 PubMed
  142. M. Hernandez , J. Choi , and G. Medioni , “ Laser scan quality 3-D face modeling using a low-cost depth camera,” in 2012 Proceedings of the 20th European Signal Processing Conference (EUSIPCO) ( IEEE, 2012), pp. 1995–1999.
  143. K. E. Peyer , M. Morris , and W. I. Sellers , “ Subject-specific body segment parameter estimation using 3D photogrammetry with multiple cameras,” PeerJ 3, e831 (2015).10.7717/peerj.83125780778PMC4359122 doi:10.7717/peerj.831 PubMed
  144. P. R. Apeagyei , “ Application of 3D body scanning technology to human measurement for clothing Fit,” Int. J. Digital Content Technol. Appl. 4, 58–68 (2010).10.4156/jdcta.vol4.issue7.6 doi:10.4156/jdcta.vol4.issue7.6
  145. P. Treleaven and J. Wells , “ 3D body scanning and healthcare applications,” Computer 40, 28–34 (2007).10.1109/MC.2007.225 doi:10.1109/MC.2007.225
  146. D. Rodbard , “ The role of regional body temperature in the pathogenesis of disease,” N. Engl. J. Med. 305, 808–814 (1981).10.1056/NEJM1981100130514067022218 doi:10.1056/NEJM198110013051406 PubMed
  147. R. C. Webb et al., “ Epidermal devices for noninvasive, precise, and continuous mapping of macrovascular and microvascular blood flow,” Sci. Adv. 1, e1500701 (2015).10.1126/sciadv.150070126601309PMC4646823 doi:10.1126/sciadv.1500701 PubMed
  148. S. Han et al., “ Battery-free, wireless sensors for full-body pressure and temperature mapping,” Sci. Transl. Med. 10, eaan4950 (2018).10.1126/scitranslmed.aan495029618561PMC5996377 doi:10.1126/scitranslmed.aan4950 PubMed
  149. J. W. Lee et al., “ Soft, thin skin-mounted power management systems and their use in wireless thermography,” Proc. Natl. Acad. Sci. U. S. A. 113, 6131–6136 (2016).10.1073/pnas.160572011327185907PMC4896718 doi:10.1073/pnas.1605720113 PubMed
  150. T. Someya et al., “ Conformable, flexible, large-area networks of pressure and thermal sensors with organic transistor active matrixes,” Proc. Natl. Acad. Sci. U. S. A. 102, 12321–12325 (2005).10.1073/pnas.050239210216107541PMC1187825 doi:10.1073/pnas.0502392102 PubMed
  151. S. C. Mukhopadhyay , “ Wearable sensors for human activity monitoring: A review,” IEEE Sens. J. 15, 1321–1330 (2015).10.1109/JSEN.2014.2370945 doi:10.1109/JSEN.2014.2370945
  152. A. Gaddam , S. C. Mukhopadhyay , S. Gupta , and H. Guesgen , “ Wireless sensors networks based monitoring: Review, challenges and implementation issues,” in 2008 3rd International Conference on Sensing Technology ( IEEE, 2008), pp. 533–538.
  153. G. Shin et al., “ Wearable activity trackers, accuracy, adoption, acceptance and health impact: A systematic literature review,” J. Biomed. Inf. 93, 103153 (2019).10.1016/j.jbi.2019.10315330910623 doi:10.1016/j.jbi.2019.103153 PubMed
  154. H. Lim et al., “ Advanced soft materials, sensor integrations, and applications of wearable flexible hybrid electronics in healthcare, energy, and environment,” Adv. Mater. 32, 1901924 (2020).10.1002/adma.20190192431282063 doi:10.1002/adma.201901924 PubMed
  155. R. Sanchez-Iborra , “ LPWAN and embedded machine learning as enablers for the next generation of wearable devices,” Sensors 21, 5218 (2021).10.3390/s2115521834372455PMC8347601 doi:10.3390/s21155218 PubMed
  156. R. Sanchez-Iborra and A. F. Skarmeta , “ TinyML-enabled frugal smart objects: Challenges and opportunities,” IEEE Circuits Syst. Mag. 20, 4–18 (2020).10.1109/MCAS.2020.3005467 doi:10.1109/MCAS.2020.3005467
  157. N. Starliper et al., “ Activity-aware wearable system for power-efficient prediction of physiological responses,” Sensors 19, 441 (2019).10.3390/s19030441PMC638735930678188 doi:10.3390/s19030441 PubMed
  158. C. Culman , S. Aminikhanghahi , and D. J. Cook , “ Easing power consumption of wearable activity monitoring with change point detection,” Sensors 20, 310 (2020).10.3390/s20010310PMC698279431935907 doi:10.3390/s20010310 PubMed
  159. C. Adans-Dester et al., “ Enabling precision rehabilitation interventions using wearable sensors and machine learning to track motor recovery,” npj Digital Med. 3, 121 (2020).10.1038/s41746-020-00328-wPMC750601033024831 doi:10.1038/s41746-020-00328-w PubMed
  160. F. Cui , Y. Yue , Y. Zhang , Z. Zhang , and H. S. Zhou , “ Advancing biosensors with machine learning,” ACS Sens. 5, 3346–3364 (2020).10.1021/acssensors.0c0142433185417 doi:10.1021/acssensors.0c01424 PubMed
  161. S. Benatti et al., “ A versatile embedded platform for EMG acquisition and gesture recognition,” IEEE Trans. Biomed. Circuits Syst. 9, 620–630 (2015).10.1109/TBCAS.2015.247655526513799 doi:10.1109/TBCAS.2015.2476555 PubMed
  162. A. Moin et al., “ A wearable biosensing system with in-sensor adaptive machine learning for hand gesture recognition,” Nat. Electron. 4, 54–63 (2021).10.1038/s41928-020-00510-8 doi:10.1038/s41928-020-00510-8
  163. X. Liu et al., “ The virtual trackpad: An electromyography-based, wireless, real-time, low-power, embedded hand-gesture-recognition system using an event-driven artificial neural network,” IEEE Trans. Circuits Syst. II 64, 1257–1261 (2017).10.1109/TCSII.2016.2635674 doi:10.1109/TCSII.2016.2635674
  164. V. D. Nagarajan et al., “ Artificial intelligence in the diagnosis and management of arrhythmias,” Eur. Heart J. 42, 3904–3916 (2021).10.1093/eurheartj/ehab54434392353PMC8497074 doi:10.1093/eurheartj/ehab544 PubMed
  165. G. Vavasour , O. M. Giggins , J. Doyle , and D. Kelly , “ How wearable sensors have been utilised to evaluate frailty in older adults: A systematic review,” J. Neuroeng. Rehabil. 18, 112 (2021).10.1186/s12984-021-00909-034238323PMC8268245 doi:10.1186/s12984-021-00909-0 PubMed
  166. D. M. Sherrill , M. L. Moy , J. J. Reilly , and P. Bonato , “ Using hierarchical clustering methods to classify motor activities of COPD patients from wearable sensor data,” J. Neuroeng. Rehabil. 2, 16 (2005).10.1186/1743-0003-2-1615987518PMC1188068 doi:10.1186/1743-0003-2-16 PubMed
  167. R. R. Fletcher , M.-Z. Poh , and H. Eydgahi , “ Wearable sensors: Opportunities and challenges for low-cost health care,” in 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology ( IEEE, 2010), pp. 1763–1766.10.1109/IEMBS.2010.562673421096416 doi:10.1109/IEMBS.2010.5626734 PubMed
  168. J. Seppälä et al., “ Mobile phone and wearable sensor-based mHealth approaches for psychiatric disorders and symptoms: Systematic review,” JMIR Mental Health 6, e9819 (2019).10.2196/mental.981930785404PMC6401668 doi:10.2196/mental.9819 PubMed

Attribution. Tucker Stuart, Jessica Hanna, Philipp Gutruf. Wearable devices for continuous monitoring of biosignals: Challenges and opportunities. APL Bioengineering (2022);6(2). doi:10.1063/5.0086935 © 2022 Author(s). Licensed under CC BY 4.0. Reproduced from the open-access article via Europe PMC (PubMed 35464617). Text, tables and references reproduced from the open-access article; figures and images are not reproduced and no wording was changed.