Definition and research guide
This page combines a MeSH definition, publication statistics and selected research abstracts. It is a starting point for reading the literature, not a medical textbook or a systematic evidence review.
Content available: 4 complete abstracts (853 words), 10 references. Full article text is not stored or reproduced here; follow the PMID, DOI or PMC links to read the original sources and their access terms.
Definition
The fluid excreted by the sweat glands. It consists of water containing sodium chloride, phosphate, urea, ammonia, and other waste products.
Definition: NLM Medical Subject Headings (MeSH) scope note (Public domain (U.S. National Library of Medicine); attribution requested). View the MeSH record.
Also known as: Sweats.
Where it fits in the MeSH classification
- Broader topics
- Bodily Secretions
Related concepts
Research landscape
PubMed indexes 5,624 records tagged with the MeSH heading “Sweat” (counts retrieved 2026-10-31). 1,525 of them (27.1%) were published from 2020 onward, and the busiest period so far is through 1999 with 2,434 records.
Reviews account for 430 records (7.6%) and meta-analyses for 3. Randomized controlled trials number 106 (1.9%) as a share of all records on the topic. Randomized trials make up only a small share of this literature, so much of what is known comes from laboratory, observational or descriptive work.
Show the data
| Period | Records |
|---|---|
| through 1999 | 2,434 |
| 2000-2009 | 590 |
| 2010-2019 | 1,075 |
| 2020 onward | 1,525 |
Publication-type chart data
| Type | Records | Share |
|---|---|---|
| Reviews | 430 | 7.6% |
| Meta-analyses | 3 | 0.1% |
| Randomized controlled trials | 106 | 1.9% |
Method: PubMed query "Sweat"[MeSH Terms] with publication-type and date filters, retrieved 2026-10-31.
Reading the evidence in anatomy and physiology
Anatomy describes how body structures are built and physiology describes how they normally work, so most findings here are descriptive or mechanistic rather than evidence about treatment. Much of what is known comes from dissection, imaging, tissue studies and experiments in animals, and measurements in healthy volunteers can differ from those in people with disease or at different ages. Normal ranges vary between individuals and populations. Check whether a result was measured in people or in another species, the age and health of the participants, and the method used.
Evidence from open-access studies
These open-access studies come from PubMed’s best-match results for this heading (papers whose main topic it is), ranked here by citation count, with one recent addition. Each abstract is reproduced in full under its recorded open licence so that you can read the authors’ own words. They illustrate the literature; they are not a systematic summary of it. Citation counts measure attention, not reliability or clinical benefit.
| Study / authors | Year | Source label / design | Europe PMC citations | Licence / source |
|---|---|---|---|---|
| Sweating Rate and Sweat Sodium Concentration in Athletes: A Review of Methodology and Intra/Interindividual Variability | 2017 | Review article Design not recorded in structured metadata | 253 | cc by PMID 28332116 · DOI · PMC5371639 |
| A wearable patch for continuous analysis of thermoregulatory sweat at rest | 2021 | Research article Design not recorded in structured metadata | 239 | cc by PMID 33758197 · DOI · PMC7987967 |
| Physiological mechanisms determining eccrine sweat composition | 2020 | Review article Design not recorded in structured metadata | 194 | cc by PMID 32124007 · DOI · PMC7125257 |
| The molecular signature of heat stress in sweat reveals non-invasive biomarker candidates for health monitoring | 2025 | Research article Design not recorded in structured metadata | 9 | cc by PMID 40269247 · DOI · PMC12019370 |
Sweating Rate and Sweat Sodium Concentration in Athletes: A Review of Methodology and Intra/Interindividual Variability [1]
Abstract reading summary — source excerpts
- Opening excerpt
- Athletes lose water and electrolytes as a consequence of thermoregulatory sweating during exercise and it is well known that the rate and composition of sweat loss can vary considerably within and among individuals.
- Closing excerpt
- In summary, sweat testing can be a useful tool to estimate athletes' SR and sweat Na+ loss to help guide fluid/electrolyte replacement strategies, provided that data are collected, analyzed, and interpreted appropriately.
- Interpretation limits
- Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (264 words)
Athletes lose water and electrolytes as a consequence of thermoregulatory sweating during exercise and it is well known that the rate and composition of sweat loss can vary considerably within and among individuals. Many scientists and practitioners conduct sweat tests to determine sweat water and electrolyte losses of athletes during practice and competition. The information gleaned from sweat testing is often used to guide personalized fluid and electrolyte replacement recommendations for athletes; however, unstandardized methodological practices and challenging field conditions can produce inconsistent/inaccurate results. The primary objective of this paper is to provide a review of the literature regarding the effect of laboratory and field sweat-testing methodological variations on sweating rate (SR) and sweat composition (primarily sodium concentration [Na+]). The simplest and most accurate method to assess whole-body SR is via changes in body mass during exercise; however, potential confounding factors to consider are non-sweat sources of mass change and trapped sweat in clothing. In addition, variability in sweat [Na+] can result from differences in the type of collection system used (whole body or localized), the timing/duration of sweat collection, skin cleaning procedure, sample storage/handling, and analytical technique. Another aim of this paper is to briefly review factors that may impact intra/interindividual variability in SR and sweat [Na+] during exercise, including exercise intensity, environmental conditions, heat acclimation, aerobic capacity, body size/composition, wearing of protective equipment, sex, maturation, aging, diet, and/or hydration status. In summary, sweat testing can be a useful tool to estimate athletes' SR and sweat Na+ loss to help guide fluid/electrolyte replacement strategies, provided that data are collected, analyzed, and interpreted appropriately.
Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 28332116 · DOI · PMC5371639
A wearable patch for continuous analysis of thermoregulatory sweat at rest [2]
Abstract reading summary — source excerpts
- Opening excerpt
- The body naturally and continuously secretes sweat for thermoregulation during sedentary and routine activities at rates that can reflect underlying health conditions, including nerve damage, autonomic and metabolic disorders, and chronic stress.
- Closing excerpt
- By enabling sweat analysis compatible with sedentary, routine, and daily activities, these patches enable continuous, autonomous monitoring of body physiology at rest.
- Interpretation limits
- Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (150 words)
The body naturally and continuously secretes sweat for thermoregulation during sedentary and routine activities at rates that can reflect underlying health conditions, including nerve damage, autonomic and metabolic disorders, and chronic stress. However, low secretion rates and evaporation pose challenges for collecting resting thermoregulatory sweat for non-invasive analysis of body physiology. Here we present wearable patches for continuous sweat monitoring at rest, using microfluidics to combat evaporation and enable selective monitoring of secretion rate. We integrate hydrophilic fillers for rapid sweat uptake into the sensing channel, reducing required sweat accumulation time towards real-time measurement. Along with sweat rate sensors, we integrate electrochemical sensors for pH, Cl-, and levodopa monitoring. We demonstrate patch functionality for dynamic sweat analysis related to routine activities, stress events, hypoglycemia-induced sweating, and Parkinson's disease. By enabling sweat analysis compatible with sedentary, routine, and daily activities, these patches enable continuous, autonomous monitoring of body physiology at rest.
Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 33758197 · DOI · PMC7987967
Physiological mechanisms determining eccrine sweat composition [3]
Abstract reading summary — source excerpts
- Opening excerpt
- PurposeThe purpose of this paper is to review the physiological mechanisms determining eccrine sweat composition to assess the utility of sweat as a proxy for blood or as a potential biomarker of human health or nutritional/physiological status.
- Closing excerpt
- Future research that accounts for these confounding factors is needed to address the existing gaps in the literature.
- Interpretation limits
- Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (243 words)
PurposeThe purpose of this paper is to review the physiological mechanisms determining eccrine sweat composition to assess the utility of sweat as a proxy for blood or as a potential biomarker of human health or nutritional/physiological status.MethodsThis narrative review includes the major sweat electrolytes (sodium, chloride, and potassium), other micronutrients (e.g., calcium, magnesium, iron, copper, zinc, vitamins), metabolites (e.g., glucose, lactate, ammonia, urea, bicarbonate, amino acids, ethanol), and other compounds (e.g., cytokines and cortisol).ResultsIon membrane transport mechanisms for sodium and chloride are well established, but the mechanisms of secretion and/or reabsorption for most other sweat solutes are still equivocal. Correlations between sweat and blood have not been established for most constituents, with perhaps the exception of ethanol. With respect to sweat diagnostics, it is well accepted that elevated sweat sodium and chloride is a useful screening tool for cystic fibrosis. However, sweat electrolyte concentrations are not predictive of hydration status or sweating rate. Sweat metabolite concentrations are not a reliable biomarker for exercise intensity or other physiological stressors. To date, glucose, cytokine, and cortisol research is too limited to suggest that sweat is a useful surrogate for blood.ConclusionFinal sweat composition is not only influenced by extracellular solute concentrations, but also mechanisms of secretion and/or reabsorption, sweat flow rate, byproducts of sweat gland metabolism, skin surface contamination, and sebum secretions, among other factors related to methodology. Future research that accounts for these confounding factors is needed to address the existing gaps in the literature.
Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 32124007 · DOI · PMC7125257
The molecular signature of heat stress in sweat reveals non-invasive biomarker candidates for health monitoring [4]
Abstract reading summary — source excerpts
- Opening excerpt
- Heat stress is a significant public health challenge that leads to an increased risk of serious health deterioration, injuries, and loss of economic productivity.
- Closing excerpt
- Once further investigated, next-generation wearable devices for person-centered, on-skin sweat-analysing platforms could be developed that would transform health management during exposure to heat stress.
- Interpretation limits
- Verbatim excerpts from the authors’ abstract; the closing excerpt may describe a finding, limitation or recommendation. Design, population, effect size and uncertainty have not been independently extracted or appraised. Read the complete abstract and linked paper before interpreting the findings.
Read complete abstract (196 words)
Heat stress is a significant public health challenge that leads to an increased risk of serious health deterioration, injuries, and loss of economic productivity. While the gold standard for monitoring heat stress continues to remain with population-based measurements, a straight-forward person-centered approach is lacking. Sweat can supply a wealth of molecular information, ranging from protein levels to levels of metabolites; it is thus a promising monitoring biofluid. A thorough investigation of sweat's molecular signature during heat stress is called for. We conducted a cross-over study on healthy participants with personalized heat-stress visits to investigate heat stress's proteomic and molecular signatures in sweat. Through mass-spectrometry analysis, we identified multiple candidate biomarkers ranging from amino acids to microbiome metabolites and proteins. To the best of our knowledge, these biomarker candidates represent the first successful approach to metabolically differentiate between various heat stressors thereby enabling their acute monitoring. While these biomarker candidates need further investigation to confirm their clinical value, many have already been identified as directly associated with heat stress in animals and plants. Once further investigated, next-generation wearable devices for person-centered, on-skin sweat-analysing platforms could be developed that would transform health management during exposure to heat stress.
Abstract reproduced from the open-access article under the recorded cc by licence; © the authors. PMID 40269247 · DOI · PMC12019370
Key reviews and meta-analyses
The most cited review-type papers among PubMed’s best-match results for this heading, listed with bibliographic details only. Follow the links for the full text and access terms.
- Research article Skin-interfaced systems for sweat collection and analytics [5]
- Research article Hydration for recreational sport and physical activity [6]
- Research article Diagnostic sweat testing: the Cystic Fibrosis Foundation guidelines [7]
- Research article Wearable Sensors for Biochemical Sweat Analysis [8]
- Research article Eccrine sweat gland development and sweat secretion [9]
- Research article Sweat testing to evaluate autonomic function [10]
References
- Baker LB. Sweating Rate and Sweat Sodium Concentration in Athletes: A Review of Methodology and Intra/Interindividual Variability. . 2017. PMID 28332116 · DOI · PMC5371639
- Nyein HYY, Bariya M, Tran B, Ahn CH, Brown BJ, Ji W, et al.. A wearable patch for continuous analysis of thermoregulatory sweat at rest. . 2021. PMID 33758197 · DOI · PMC7987967
- Baker LB, Wolfe AS. Physiological mechanisms determining eccrine sweat composition. . 2020. PMID 32124007 · DOI · PMC7125257
- Brasier N, Niederberger C, Zanella M, Othman A, Schlapbach R, Kunz L, et al.. The molecular signature of heat stress in sweat reveals non-invasive biomarker candidates for health monitoring. . 2025. PMID 40269247 · DOI · PMC12019370
- Choi J, Ghaffari R, Baker LB, Rogers JA. Skin-interfaced systems for sweat collection and analytics. Sci Adv. 2018. PMID 29487915 · DOI · PMC5817925
- Kenefick RW, Cheuvront SN. Hydration for recreational sport and physical activity. Nutr Rev. 2012. PMID 23121349 · DOI
- LeGrys VA, Yankaskas JR, Quittell LM, Marshall BC, Mogayzel PJ, Cystic Fibrosis Foundation. Diagnostic sweat testing: the Cystic Fibrosis Foundation guidelines. J Pediatr. 2007. PMID 17586196 · DOI
- Bandodkar AJ, Jeang WJ, Ghaffari R, Rogers JA. Wearable Sensors for Biochemical Sweat Analysis. Annu Rev Anal Chem (Palo Alto Calif). 2019. PMID 30786214 · DOI
- Cui CY, Schlessinger D. Eccrine sweat gland development and sweat secretion. Exp Dermatol. 2015. PMID 26014472 · DOI · PMC5508982
- Illigens BM, Gibbons CH. Sweat testing to evaluate autonomic function. Clin Auton Res. 2009. PMID 18989618 · DOI · PMC3046462
About this article
- Sources
- NLM Medical Subject Headings (definition, synonyms); NCBI PubMed (counts, identifiers); Europe PMC (open-access abstracts and citation counts).
- Verification
- Every reference was resolved against PubMed on 2026-10-31; title, year and DOI matched.
- Review state
- automated source verified; no human expert review has been recorded yet.
- Version
- 1, last updated 2026-10-31.
See how EvidenceLib is built. Spotted an error? Email support@evidencehelix.com.
Evidence strength
EvidenceHelix's computed view of the study designs behind this topic: how common meta-analyses, randomized trials and reviews are, how recent the literature is, and a plain-language reading. It describes the design mix of the literature. It is not a quality appraisal of any study, and it is not medical advice.